System Reset Functions
42
432-0003-00-10 rev 140 M-Series Operator’s Manual
Restore Factory Defaults
Select this item to restore the M-Series to its factory default settings. The
camera will prompt the user to confirm if the camera is to be restored to
the factory default settings.
Refer to Factory Default Settings table for a list of the factory default set-
tings.
System Reset Functions
JCU Reset
Occasionally it may be necessary to reset the JCU. Simultaneously pressing
the MENU and USER buttons for >3 seconds causes the JCU to reset.
Unplugging and plugging the Ethernet will also cause the JCU to lose power
temporarily and reset.
Camera Reset
Severe vibrations or shock may cause the camera gimbal assembly to
rotate or tilt and cause the Position Indicator to be inaccurate. To reset the
camera and cause the gimbal assembly to go through its initial pan/tilt
cycle, repeatedly press the HOME button 4 times.
Note
:
the High Power Standby and High Motor Torque settings can be
enabled to provide the camera with a better ability to withstand shock and
vibration at high rates of speed or in high seas.
About/Help Menu