427-0089-00-12 Version 100
July 2016
56
3
Advanced Configuration
Video Analytics Alarm to Email:
Shown at the right is an
example of an alarm rule that causes an email notification (with a
snapshot image) to be sent when a motion alarm occurs in
Analytics Region 1 (Area or Tripwire).
Refer to
Creating Analytics Regions, pg. 46
).
The Alarm Source Device Type is set to
Video Analytics
with
Alarm Id set to “
1
” corresponding to Analytics Area 1.
The
Send Notification
action uses a Msg System and a
Notification List that are set up in the Services menu (refer to
Msg Systems, pg. 30
). The email includes alarm information,
including the Area ID and if it is a human or vehicle alarm. When
an email is sent, the Alarm Manager can attach a snapshot from
the camera to the email. In Attach Image File,
All Non
Radiometric
is selected for the type of image since the alarm
type is
Analytics
.
GPIO Input to Snapshot:
In the example rule shown at the right
the source type of the alarm is GPIO, with the Input ID set to 0,
which corresponds with the input IO 0 (refer to
Devices Menu, pg.
51
), then takes a snapshot and stores it in the
Media Browser, pg.
58
.
The Action is set to
Capture Image File
, and that causes a
snapshot to be saved in the Media Browser folder when the
alarm occurs (see
Files Menu, pg. 57
). The Snapshot type can be
set to
All Non Radiometric
(a normal JPEG image),
Radiometric
(a special type of JPEG with temperature data), or
All
(saves both types).
GPIO Output from Motion Alarm:
The final example shows an
alarm rule that causes a GPIO output when a motion alarm is
detected. The source Alarm Id set to 1 corresponds to Region
number 1 on the Analytics Setup page.
Note
: the Associated I/O Port is set to 0, and the Associated I/O
Index is set to 1 (corresponding to Input/Output 1).
The GPIO Output State Mode can be set as
Bound
or
Unbound
.
If
Bound
, the output turns on when an alarm occurs and turns off
when the alarm is cleared or the Output Reset Interval is reached
(see
Devices Menu, pg. 51
).
If
Unbound
, the output turns on when an alarm occurs and
remains on until it is reset by the Output Reset Interval time-out
or by a command from the network.