FLIR FC-Series ID Скачать руководство пользователя страница 2

© 2016 FLIR Systems, Inc. All rights reserved worldwide. No parts of this manual, in whole or in part, may be 

copied, photocopied, translated, or transmitted to any electronic medium or machine readable form without the 

prior written permission of FLIR Systems, Inc.
Names and marks appearing on the products herein are either registered trademarks or trademarks of FLIR 

Systems, Inc. and/or its subsidiaries. All other trademarks, trade names, or company names referenced herein are 

used for identification only and are the property of their respective owners.
This product is protected by patents, design patents, patents pending, or design patents pending.
The contents of this document are subject to change without notice. 

 

For additional information visit 

www.flir.com

 or write to FLIR Systems, Inc.

FLIR Systems, Inc.

 

6769 Hollister Avenue

 

Goleta, CA 93117

Support: 

http://www.flir.com/security/display/?id=71083

.

Important Instructions and Notices to the User:

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This 

device may not cause harmful interference, and (2) this device must accept any interference received, including 

interference that may cause undesired operation.
Modification of this device without the express authorization of FLIR Systems, Inc. may void the user’s authority 

under FCC rules to operate this device.

Note 1:

 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to 

part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference 

when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate 

radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful 

interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful 

interference in which case the user will be required to correct the interference at the user’s own expense.

Note 2:

 

If this equipment came with shielded cables, it was tested for compliance with the FCC limits for 

a Class A digital device using shielded cables and therefore shielded cables must be used with the 

device

Industry Canada Notice

 

This Class A digital apparatus complies with Canadian ICES-003.

Avis d’Industrie Canada

:

 

Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

 

Proper Disposal of Electrical and Electronic Equipment (EEE)

The European Union (EU) has enacted Waste Electrical and Electronic Equipment Directive 2002/

96/EC (WEEE), which aims to prevent EEE waste from arising; to encourage reuse, recycling, and 

recovery of EEE waste; and to promote environmental responsibility.
In accordance with these regulations, all EEE products labeled with the “crossed out wheeled bin” 

either on the product itself or in the product literature must not be disposed of in regular rubbish bins, 

mixed with regular household or other commercial waste, or by other regular municipal waste 

collection means.  Instead, and in order to prevent possible harm to the environment or human 

health, all EEE products (including any cables that came with the product) should be responsibly 

discarded or recycled.

To identify a responsible disposal method nearby, please contact the local waste collection or recycling service, the 

original place of purchase or product supplier, or the responsible government authority in the area. Business users 

should contact their supplier or refer to their purchase contract.

Document History

Version

Date

Comment

100

June 2016

Initial Release

Содержание FC-Series ID

Страница 1: ...Installation Manual FC Series ID...

Страница 2: ...requency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is like...

Страница 3: ...er 12 1 4 2 Installing the microSD Card 13 1 4 3 Bench Testing 13 1 4 4 Analog Video Connections 13 1 4 5 Connecting Power 13 1 4 6 GPIO Connections 14 1 4 7 Ethernet 15 1 4 8 Camera Grounding 15 1 4...

Страница 4: ...1 Setup Menu 38 3 1 1 Video Setup 39 3 1 2 Thermal Image Setup 42 3 1 3 Video Analytics Setup 45 3 2 Maintenance Menu 49 3 2 1 Sensor Menu 49 3 2 2 Files Menu 57 3 2 3 Product Info Menu 59 Image from...

Страница 5: ...gs and Cautions Warning Caution 1 2 References FLIR Doc 427 00XX YY 41 FC Series ID Interconnect Document available from the FLIR website provides further details regarding mechanical dimensions and m...

Страница 6: ...e from the camera is required In installations using analog video and conventional power 24 Vac is commonly used in many installations an RG59U coaxial cable and a three conductor power cable are inst...

Страница 7: ...llows the Concealed Cable Wall Mount to be mounted to a pole 75 mm 3 in min to 180 mm 7 in larger pole diameter requires use of customer supplied band clamps FC Series ID Cold Weather Kit PN 421 0056...

Страница 8: ...and Sealing pg 15 for more information 1 3 5 Camera Mounting for Rear Cable Access The FC Series ID camera can be secured to the mount with two in line 1 4 20 threaded fasteners on the top or bottom o...

Страница 9: ...ment may vary depending on the installation Maintain the bend radius per the recommendation of the cable manufacturer The typical cable bend radius is 50 75mm 2 3 in 1 3 6 Camera Mounting with Conceal...

Страница 10: ...d is not used Depending on the needs of the installation the sunshield can be positioned in the neutral middle position or slightly forward or rearward To change the position of the sunshield temporar...

Страница 11: ...ide the camera enclosure There is a grounding wire connected inside the case to the top cover as shown If it or any of the grounding wires is temporarily disconnected during the installation it must b...

Страница 12: ...h a 60 mm or a 75 mm lens are shipped from the factory with the supplemental lens heater off These cameras require the cold weather kit accessory for installations that require using the supplemental...

Страница 13: ...ed should be rated as RG 59 U or better to ensure a quality video signal Note 1 4 5 Connecting Power The camera can be powered with a conventional Vac or Vdc power supply rather than PoE Prior to maki...

Страница 14: ...sh in spring contact accepts 20 24 AWG conductors Strip conductor ends to 6 mm Input Signal The camera can receive an external input signal on accessory connector J5 pins 4 and 5 when these pins are c...

Страница 15: ...they should be reconnected prior to closing the camera 1 4 9 Rear Access Cable Gland Sealing Proper installation of cable sealing gland and use of appropriate elastomer inserts is critical to long te...

Страница 16: ...Note To ensure a water tight seal when using the supplied rear cable gland cable dimensions must be within the minimum and maximum as described in Table 1 3 1 5 Concealed Cable Mount Accessory Do not...

Страница 17: ...t that were removed with the cable gland Step 3 Use a 3 mm hex key to loosen the four captive screws and remove the seal plate o ring and plug Step 4 Install the wall mount PN 4129742 to the wall and...

Страница 18: ...indicated in Camera Connections pg 11 Ensure that any ground wire that was removed during installation is reconnected Replace the cover and tighten the four 3 mm hex screws to 1 8 n m 16 0 in lbs Caut...

Страница 19: ...ermalized focus free General Weight 4 65 lb 2104 g with sun shield 13 mm 19 mm 35 mm 5 25 lb 2381 g with sun shield 60 mm 5 41 lb 2454 g with sun shield 75 mm Dimensions L W H 9 2 x 4 6 x 4 1 without...

Страница 20: ...to 70 C 58 F to 158 F continuous 40 C to 70 C 40 F to 158 F cold start Storage Temperature range 55 C to 85 C 67 F to 185 F Humidity 0 95 relative Shock MIL STD 810G Method 514 6 Vibration IEC 60068...

Страница 21: ...nected to the network it functions as a server it provides services such as camera control video streaming network communications and geo referencing capabilities The communications protocol used is a...

Страница 22: ...later from the FLIR Firmware Software Downloads page at http www flir com security display id 73533 b Unzip the utility then double click to run the executable file DNA exe All the units on the VLAN...

Страница 23: ...t a PC or laptop to the switch also Use a web browser to access and test the camera as described below and if necessary make configuration changes prior to installation 2 3 1 Log in to the Camera Web...

Страница 24: ...an NVR For slow communication links if there is a problem displaying the video image it may help to slow down the frame rate Help At the top of the page the Help menu displays software version informa...

Страница 25: ...s being used Web Control Panel The control buttons on the right side of the page provide a way to control the camera in a limited number of ways When the mouse cursor is positioned over a button a too...

Страница 26: ...eo Analytics Setup pg 45 2 4 Basic Camera Configuration The following procedures describe how to do the most common bench test camera configuration steps such as setting the camera IP address and host...

Страница 27: ...nus on the left side of the page The LAN Settings Services and Security Options selections are described below The expert login has access to these Server pages but will only see the security settings...

Страница 28: ...sage will appear to indicate the network interface must be restarted Once the IP address of the camera is changed the PC may no longer be on the same network and therefore may not be able to access th...

Страница 29: ...er or can be entered manually If NTP mode is selected the NTP server information can be entered The Nexus server must be stopped before changes can be saved After saving changes it is necessary to res...

Страница 30: ...email server is on a different network ensure the IP default gateway and DNS servers are configured in the LAN Settings refer to LAN Settings pg 27 Configure the Msg Systems page with mail server inf...

Страница 31: ...tion that is active and running and another configuration that is saved and possibly different than the running configuration The message at the bottom of the page indicates the saved configuration is...

Страница 32: ...IP addresses are entered select the Save button to save the changes To maintain security of the system set new passwords for each of the three login accounts requires the admin login user The user acc...

Страница 33: ...they easily radiate energy in the portion of the infrared spectrum that the camera can detect the long wave infrared LWIR Even very cold objects like ice and snow radiate this type of energy This is...

Страница 34: ...ly wipe the lens clean when you can visually see contamination on the surface Use the following procedure and solvents as required Acetone removal of grease Ethanol removal of fingerprints and other c...

Страница 35: ...ghly the same temperature Compare this to imagery right after sunset when objects in the image may be radiating heat energy that has been absorbed during the day due to solar loading Greater temperatu...

Страница 36: ...eristics of the cable will be influenced by the physical environment through which the cable is run and the method of installation Use only high quality cable and ensure the cable is suitable to the e...

Страница 37: ...g the sun but looking at the sun will not permanently damage the sensor In fact the thermal imaging camera often provides a considerable advantage over a conventional camera in this type of back lit s...

Страница 38: ...ration changes are made with the web browser the settings are saved to a configuration file It is a good idea to make a backup of the existing configuration file prior to making changes and another ba...

Страница 39: ...provide high quality full frame rate video streams with reasonable bandwidth usage The default settings for each video stream provide high quality full frame rate video In general for most installatio...

Страница 40: ...A smaller I Frame Interval results in higher bandwidth more full frames sent and better video quality A higher I Frame Interval number means fewer I frames are sent and therefore results in lower ban...

Страница 41: ...nal security environments There are many parameters and factors related to network infrastructure protocols codecs and so on that can affect the quality and bit rate of a video stream when it is estab...

Страница 42: ...single JPEG image a snapshot is displayed in the upper right hand corner To update this image at any time select the Refresh button in the upper right This will cause the entire page to refresh includ...

Страница 43: ...TT Mean setting determines the temperature that is at the middle of the 256 shades of gray available to the camera Higher values allow more detail in hotter scenes while lower values allow more detail...

Страница 44: ...ay cause an overall image improvement Refer to Image freezes momentarily pg 34 Misc Lookup Table Each Look Up Table LUT provides a different display of the various detected levels of thermal energy as...

Страница 45: ...r sending an email or can send an alarm to other systems or devices Use the Maintenance menu to define the actions resulting from each alarm condition Alarm Manager pg 54 Analytics page Use this page...

Страница 46: ...Boxes detected motion classified as vehicle human or object of interest is shown with a box around it labeled H V or O No Boxes detected motion is not shown with a box Lines show the track of an obje...

Страница 47: ...to set the area specific parameters Once the parameters are set up properly scroll down and click the Save button Analytics Calibration When turned on the video analytics provide recognition of movin...

Страница 48: ...subject Click Save Based on these settings the analytics calculate a human size that is proportional to the near and far size calibration over the detection area The vehicle size is extrapolated from...

Страница 49: ...tenance menus are accessible including Sensor Files and Product Info 3 2 1 Sensor Menu The configuration changes commonly used are done through the Sensor menu Described below are configuration steps...

Страница 50: ...mera from a web browser Refer to Security Options pg 32 to add an allowed IP address to the list in the Restrict Web Configuration section VMS Remote If the camera is used with a third party VMS that...

Страница 51: ...t Interval is used to automatically reset the output signal after a set time Setting the value to 0 prevents the output from resetting automatically after a timeout It can be reset with a client progr...

Страница 52: ...e Click on the Save button to save any changed settings The changes will not take effect until the server is stopped and started Refer to the following sections for a description of how to combine the...

Страница 53: ...On Screen Display Use the OSD page to turn on and configure the On Screen Display OSD options It may be desirable to display text information such as the name of the camera or the date time as an ove...

Страница 54: ...device server on the network such as a radar server input output server ground sensor fence system or other security sensor Alarm Source The source of alarms for the FC Series ID camera is typically i...

Страница 55: ...It is possible to attach an image with the notification when it is sent To attach a snapshot select an option from the Attach Image File pull down list The option All Non Radiometric sends a normal J...

Страница 56: ...GPIO with the Input ID set to 0 which corresponds with the input IO 0 refer to Devices Menu pg 51 then takes a snapshot and stores it in the Media Browser pg 58 The Action is set to Capture Image File...

Страница 57: ...e to view the Nexus Configuration File perform Backup Recovery of local files on the camera and perform Upload Download of configuration files to another computer for backup or to install a new config...

Страница 58: ...e image In this case IR0 is the only sensor Select Download to download the selected file the PC Select Refresh to check for any additional images since landing on the Media Browser page Select Edit t...

Страница 59: ...dentification page are described below Use the Identification page to change the Friendly Name which appears in FLIR Latitude by default You can also include the Friendly Name on the video feeds and a...

Страница 60: ...2 Version 100 Date July 2016 FLIR Systems Inc 6769 Hollister Ave Goleta CA 93117 USA Corporate Headquarters FLIR Systems Inc 27700 SW Parkway Ave Wilsonville OR 97070 USA Support http www flir com sec...