![FLIR F-304 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/flir/f-304/f-304_installation-manual_2306148005.webp)
427-0030-00-12 Version 180
March 2018
5
1
F-Series Camera Installation
1.3
Camera Overview
The F-Series camera is both an analog and an IP camera. The video from the camera can be viewed
over a traditional analog video network or it can be viewed by streaming it over an IP network using
MPEG-4, M-JPEG, and H.264 encoding. Analog video will require a connection to a video monitor or
an analog matrix/switch. The IP video will require a connection to an Ethernet network switch and a
computer with the appropriate software for viewing the video stream.
1.4
Installation Overview
The F-Series Camera is an infrared thermal imaging camera intended for outdoor applications, and
can be installed in a fixed location or on a pan/tilt mechanism.
The F-Series
camera is intended to be mounted on a medium-duty fixed pedestal mount or wall mount
commonly used in the CCTV industry. Cables will exit from the back of the camera housing. The mount
must support up to 30 lbs. (15 KG).
1.4.1
Camera Connection Options
Camera connections are made through water-tight cable gland seals on the rear of the camera. Refer
to
Cable Gland Sealing, pg. 7
to ensure the glands are used correctly and the connections are properly
sealed.
The camera can be powered with a conventional power supply using 21 - 30 VAC or 21 - 30 VDC.
The F-Series Camera can produce analog or digital (IP) video output (or both). Analog video will
require a connection to a video monitor or an analog video matrix switch.
An Ethernet connection is provided for IP video streaming and for command and control
communications. A web browser can be used for camera configuration and maintenance (software/
firmware updates). On some models, a web browser can also be used for IP video streaming and for
command and control.
For analog installations that are not using Ethernet/IP, a serial cable (RS232 or RS422) can optionally
be connected and used for command and control communications, supporting either Pelco D or Bosch
protocols. In installations using analog video and serial communications, it is recommended an
Ethernet cable should also be installed for camera configuration, operation, and troubleshooting.
For installations where the camera is mounted on a tower or pole or other location that may be difficult
to access, it is recommended the Ethernet connection should be installed from the camera down to
ground level at a minimum, to allow easier access.