![FLIR F-304 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/flir/f-304/f-304_installation-manual_2306148015.webp)
427-0030-00-12 Version 180
March 2018
15
1
F-Series Camera Installation
Note:
General
Weight
~10.2 lb (4.8 kg); Configuration Dependent
Dimensions (L, W, H)
18.1" × 5.5" × 6.3"
(460 × 140 × 160 mm)
Input Voltage
24 Vac (21-30 Vac)
24 Vdc (21-30 Vdc)
Power Consumption
24 Vdc = 10 W (max no heater); 46 W (max w/ heaters)
24 Vac = 15 VA (max no heater); 51 VA (max w/ heaters)
Inrush Current
< 5 A for DC supply with slew rate > 10 ms
< 19 A for AC power supply with slew rate > 4.17 ms
Environmental
IP Rating (dust & water ingress) IP66
Operating Temperature Range -50°C to 70°C continuous operation
-40°C to 70°C cold start
Storage Temperature Range
-55°C to 85°C
Humidity
0-95% relative
Shock
MIL-STD-810F Transportation
Vibe
IEC 60068-2-27
De-Icing / Anti-Icing
MIL-STD-810F, Method 521.1
Power consumption is independent of the input voltage when the heater is off. The power drawn by the heaters increases with
the input voltage to a maximum at 30 Volts.
Compliance &
Certifications
EN 61000-6-4: 2007 Class A/CISPR 22: 2005 Class A
EN 61000-3-3: 1995+A1:2001+A2:2005
EN 61000-3-2: 2006
EN 50130-4: 1996+A1:1998+A2:2003
FCC Part 15, Subpart B, Class A
IP 66 (IEC 60529)
IEC 60068-2-27)