![FLIR F-304 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/flir/f-304/f-304_installation-manual_2306148010.webp)
427-0030-00-12 Version 180
March 2018
10
1
F-Series Camera Installation
1.6.2
Video Connection
The analog video connection on the back of the camera is a BNC connector. The camera also
provides an RCA video connector that can be used to temporarily monitor the video output, without
disconnecting the BNC connection.
The video cable used should be rated as RG59U or better to ensure a quality video signal.
1.6.3
Ethernet Connection
The cable gland seal is designed for use with Shielded Category 6 Ethernet cable.
1.6.4
Serial Connection
For serial communications, it is necessary to set the parameters such as the signaling standard (RS-
232 or RS-422), baud rate, number of stop bits, parity and so on. It is also necessary to select the
communication protocol used (either Pelco D or Bosch) and the camera address. By default, the serial
interface uses Pelco D, RS-422 standard, 9600 baud rate, 8/1/none, and address 1.
Note
Connect the wires of the serial cable as show in Figure 1-3. When using the RS-422 standard, ensure
the transmit pair of the camera goes to the receive pair of the other device, and vice versa.
Note
Typical Bosch systems operate using a biphase connection and the FLIR cameras do not accept
biphase signals directly. It may be necessary to install a biphase converter in order to use the Bosch
protocol.
The terminal blocks for serial connections will accept a maximum 20 AWG wire size.
IP Network
Figure 1-4: Connector and DIP Switch locations
Analog Video
(monitoring output only)
Serial Connector
for local control
Not used
Camera Power
Heater Power
Analog Video
Содержание F-304
Страница 1: ...Installation Manual F Series...