1
F-Series Camera Installation
Camera Control Protocol:
This is the communication
protocol selected for the system when operating over the
serial port. The available protocols are Pelco-D and Bosch.
Bit 3
Bit 4
Off
Off
Pelco-D
On
Off
NA
Off
On
Bosch
On
On
NA
Serial Communication Standard:
This determines the
electrical interface selected for the user serial port. The
available settings are RS422 and RS232.
Bit 5
Bit 6
Off
Off
NA
On
Off
RS422
Off
On
RS232
On
On
NA
Not Used
Bit 7
Bit 8
X
X
X
X
X
X
X
X
Software Override DIP Switch:
This setting determines
whether the system will use software settings for
configuration or if the dip switch settings will override the
software settings. Default is Off.
Bit 9
Off
Software select
On
Hardware select
Not Used
Bit 10
X
Table 1-2: Dip Switch Settings—SW102