background image

FLIR

 

DM92

 

USER

 

GUIDE

                                                                                        

Document

 

Identifier:

 

DM92

en

US_AB

 

4

1.

 

Disclaimers

 

1.1

 

Copyright

 

©

 

2014,

 

FLIR

 

Systems,

 

Inc.

 

All

 

rights

 

reserved

 

worldwide.

 

No

 

parts

 

of

 

the

 

software

 

including

 

source

 

code

 

may

 

be

 

reproduced,

 

transmitted,

 

transcribed

 

or

 

translated

 

into

 

any

 

language

 

or

 

computer

 

language

 

in

 

any

 

form

 

or

 

by

 

any

 

means,

 

electronic,

 

magnetic,

 

optical,

 

manual

 

or

 

otherwise,

 

without

 

the

 

prior

 

written

 

permission

 

of

 

FLIR

 

Systems.

 

The

 

documentation

 

must

 

not,

 

in

 

whole

 

or

 

part,

 

be

 

copied,

 

photocopied,

 

reproduced,

 

translated

 

or

 

transmitted

 

to

 

any

 

electronic

 

medium

 

or

 

machine

 

readable

 

form

 

without

 

prior

 

consent,

 

in

 

writing,

 

from

 

FLIR

 

Systems.

 

Names

 

and

 

marks

 

appearing

 

on

 

the

 

products

 

herein

 

are

 

either

 

registered

 

trademarks

 

or

 

trademarks

 

of

 

FLIR

 

Systems

 

and/or

 

its

 

subsidiaries.

 

All

 

other

 

trademarks,

 

trade

 

names

 

or

 

company

 

names

 

referenced

 

herein

 

are

 

used

 

for

 

identification

 

only

 

and

 

are

 

the

 

property

 

of

 

their

 

respective

 

owners.

 

1.2

 

Quality

 

Assurance

 

The

 

Quality

 

Management

 

System

 

under

 

which

 

these

 

products

 

are

 

developed

 

and

 

manufactured

 

has

 

been

 

certified

 

in

 

accordance

 

with

 

the

 

ISO

 

9001

 

standard.

 

FLIR

 

Systems

 

is

 

committed

 

to

 

a

 

policy

 

of

 

continuous

 

development;

 

therefore

 

we

 

reserve

 

the

 

right

 

to

 

make

 

changes

 

and

 

improvements

 

on

 

any

 

of

 

the

 

products

 

without

 

prior

 

notice.

 

1.3

 

Documentation

 

To

 

access

 

the

 

latest

 

manuals

 

and

 

notifications,

 

go

 

to

 

the

 

Download

 

tab

 

at:

 

http://support.flir.com.

 

It

 

only

 

takes

 

a

 

few

 

minutes

 

to

 

register

 

online.

 

In

 

the

 

download

 

area

 

you

 

will

 

also

 

find

 

the

 

latest

 

releases

 

of

 

manuals

 

for

 

our

 

other

 

products,

 

as

 

well

 

as

 

manuals

 

for

 

our

 

historical

 

and

 

obsolete

 

products.

 

1.4

 

Disposal

 

of

 

Electronic

 

Waste

 

As

 

with

 

most

 

electronic

 

products,

 

this

 

equipment

 

must

 

be

 

disposed

 

of

 

in

 

an

 

environmentally

 

friendly

 

way,

 

and

 

in

 

accordance

 

with

 

existing

 

regulations

 

for

 

electronic

 

waste.

 

Please

 

contact

 

your

 

FLIR

 

Systems

 

representative

 

for

 

more

 

details.

 

 

Содержание DM92

Страница 1: ...USER MANUAL FLIR MODEL DM92 True RMS Industrial Multimeter...

Страница 2: ...Function Buttons Selector Pad and Rotary Switch 9 4 4 Display Description 10 4 5 Display Icons and Indicators 10 5 OPERATION 13 5 1 Powering the Meter 13 5 2 Auto Manual Select Mode 13 5 3 Auto Manua...

Страница 3: ...tery Replacement 21 6 3 Fuse Replacement 21 6 4 Disposal of Electronic Waste 21 7 SPECIFICATIONS 22 7 1 General specifications 22 7 2 Electrical Range Specifications 23 8 TECHNICAL SUPPORT 28 9 WARRAN...

Страница 4: ...herein are used for identification only and are the property of their respective owners 1 2 Quality Assurance The Quality Management System under which these products are developed and manufactured ha...

Страница 5: ...ge If you do not do this damage to the instrument and injury to persons can occur Do not replace the batteries before you remove the test leads This can cause damage to the instrument and can cause in...

Страница 6: ...mage to the protection This symbol adjacent to another symbol or terminal indicates that the user must refer to the manual for further information This symbol adjacent to a terminal indicates that und...

Страница 7: ...e service 3 1 Key Features 4000 40 000 counts extra large digital dual display Auto selection AC DC in voltage and current modes On screen menu selection and navigator key drive Variable frequency dri...

Страница 8: ...low 7 EXIT Button 8 HOLD Lock Button 9 Work Light Button 10 Rotary Function Switch 11 Positive Probe Input Jack for A Current 12 Positive Probe Input Jack for mA Current 13 COM negative Probe Input Ja...

Страница 9: ...The meter can measure current through the probe inputs 4 3 Function Buttons Selector Pad and Rotary Switch Use this button to select Auto select or Manual select mode see section 5 2 Auto Manual sele...

Страница 10: ...es the reading on the main display 4 5 Display Icons and Indicators Indicates that the meter is measuring stabilized voltage Indicates that the measured voltage is greater than 30 V AC or DC Indicates...

Страница 11: ...ocked mode Indicates the active memory location 1 99 Indicates the battery voltage status Indicates that the auto power off function is enabled Indicates that the meter is measuring AC current or volt...

Страница 12: ...icon Silent mode icon 4 5 1 Probe Indicator When the probe leads are not plugged into the correct jack sockets for the measurement selected by the function switch PROBE is displayed 4 5 2 Out of rang...

Страница 13: ...inactivity see section 5 11 9 Setup mode The meter beeps three times 10 seconds before powering off Press any button or turn the Rotary Switch to prevent the meter from powering off The auto power of...

Страница 14: ...lack probe lead into the negative COM terminal and the red probe lead into the positive terminal 3 Use the button to select AC DC or AC DC voltage measurement The indicator will be displayed for AC me...

Страница 15: ...or will be displayed 3 Insert the black probe lead into the negative COM terminal and the red probe lead into the positive terminal 4 Touch the tips of the probe across the diode or semiconductor junc...

Страница 16: ...isplay 6 To avoid electrical shock disconnect the thermocouple adapter before turning the function switch to another position 5 10 Current Measurements Current is measured by disconnecting the part un...

Страница 17: ...pass filter VFD mode is available when measuring AC voltage or AC current 1 Select and enable VFD mode as described in section 5 11 1 Selecting the Mode 5 11 3 Peak Mode ACV and ACA only In Peak mode...

Страница 18: ...In dBm mode the meter displays AC voltage measurements in dB or dBm on the secondary display dB and dBm are defined as follows dB 20 log VAC 1 dBm 20 log VAC 0 7746 1 Select and enable dBm mode as de...

Страница 19: ...active For more information see section 5 12 Normal hold mode and Auto hold mode 1 Select and enable Setup mode as described in section 5 11 1 Selecting the mode 2 Use the up down arrows button to cyc...

Страница 20: ...ue The current reading is displayed on the main display The held reading on the secondary display will not change unless the difference between this held reading and any new reading is greater than 50...

Страница 21: ...before it displays an out of tolerance voltage 1 To avoid electrical shock disconnect the meter if connected to a circuit remove the probe from the terminals and set the function switch to the OFF pos...

Страница 22: ...F 10 C to 30 C 85 RH 86 F to 104 F 30 C to 40 C 75 RH 104 F to 122 F 40 C to 50 C 45 RH Storage Temperature RH 22 F to 140 F 30 C to 60 C 0 80 RH batteries not fitted Temperature Coefficient 0 1 x spe...

Страница 23: ...cified 1 Below 10 or range add 10d to accuracy 2 Frequency range 1k to 2k Hz Input protection 1000 V DC or 1000 V AC RMS Input impedance mV 1 M 100 pF V 10M 100 pF Bandwidth 40 Hz to 20kHz Minimum res...

Страница 24: ...ied 10 00 A 1 Below 5 of the AC range add 20dgt to the accuracy 2 Below 10 of range add 10 dgt to accuracy Input protection Equipped with a high energy fuse mA 440 mA 1000 V IR 10 kA fuse Bussmann DMM...

Страница 25: ...stic of VFD Approx 24 dB Table 7 4 Frequency Counter Range Resolution Accuracy 400 00 Hz 0 01 Hz 5 dgt 4 0000 kHz 0 1 Hz 40 000 kHz 1 Hz 100 00 kHz 10 Hz Minimum sensed frequency 5 Hz Table 7 5 Freque...

Страница 26: ...pprox 0 1 mA Table 7 7 Continuity check Resolution of specifications in the 3 digit mode Range Resolution Accuracy 400 0 100 m 0 2 2 dgt Input protection 1000 V DC or 1000 V AC RMS Maximum open circui...

Страница 27: ...dgt 400 0 F 100 nF 0 9 2 dgt 4 000 mF 1 F 1 2 20 dgt 40 00 mF 10 F 2 0 20 dgt Input protection 1000 V DC or 1000 V AC RMS Table 7 10 Temperature Range Resolution Accuracy 328 F to 2192 F 0 1 F 1 0 36...

Страница 28: ...Warranty are MR7x CM7x CM8x DM9x IM7xand VP5x not including accessories which may have their own warranty 3 WARRANTY PERIODS For purposes of the The Limited Lifetime Warranty Lifetime is defined as s...

Страница 29: ...ttp www flir com to request an evaluation and obtain an RMA Purchaser is solely responsible for complying with all RMA instructions provided by FLIR including but not limited to adequately packaging t...

Страница 30: ...CEMENT To be eligible for warranty repair or replacement Purchaser must notify FLIR within thirty 30 days of discovering of any apparent defect in materials or workmanship Before Purchaser may return...

Страница 31: ...7070 USA Telephone 1 503 498 3547 Customer Support Technical Support Website http support flir com Technical Support Email T MSupport flir com Service and Repair Email Repair flir com Customer Support...

Отзывы: