FLIR DM284 – DMM QUICK START GUIDE Document Identifier: DM284-QS_DMM-en-US_AC
To enter Manual range mode, short press the
button. To change the range, press the
button
repeatedly until the desired range is displayed. To return to the Auto range mode, long press the
button until the Auto Range
indicator is again displayed.
MIN-MAX-AVG MEMORIES
The meter captures and displays the minimum, maximum, and average readings, updating only when a
higher/lower value is registered. The meter also averages the total sum of all recorded values. This mode is
accessed through the Advanced Menu
. Press OK on this icon
to show the maximum , minimum ,
and average readings on the display.
VFD (ACV and ACA only)
High-frequency noise is eliminated from the voltage measurement through the use of a low-pass filter (for
AC voltage/current). Navigate to the icon
with the left/right arrows and enable/disable VFD mode by
pressing the OK button.
RELATIVE MODE
This mode is accessed through the Advanced Menu
.
1.
Press OK on this icon
to capture a reference reading that subsequent measurements can be
compared with.
2.
A blue dot is shown next to the icon when this mode is selected.
3.
The reference value will be displayed next to the Relative icon.
4.
The primary display will show the difference between the measured value and the stored reference.
5.
Press OK at this icon to switch the Relative mode OFF.
PEAK MAX and PEAK MIN (ACV and ACA only)
The meter captures and displays positive/negative peaks, and updates only when a higher/lower value is
registered.
1.
Access the Peak mode
P
in the Advanced menu
.
2.
Use the up/down navigation buttons to toggle Peak Max and Peak Min.
3.
In Peak Max mode, the indicator is displayed. In Peak Min mode, the indicator is displayed.
4.
Press the
button to pause the Peak mode. Press again to continue.
MULTIMETER (DMM) SETTINGS MENU
1.
Press OK to open the main menu and Navigate to the Multimeter Settings icon
using the arrow
buttons
2.
Open the Settings menu by pressing the OK button.
3.
See the Settings menu examples below:
Diode
(Smart or Classic modes); Press OK to choose a setting.
Auto power off (APO): Press OK to open the sub-menu. Use the arrow buttons to choose the
time period after which the meter enters sleep mode. Press OK to
confirm the selection (a blue dot will appear next to the selection).
Auto hold: Use the OK button to toggle ON (blue dot) and OFF.
Temperature units. Use the OK button to toggle
o
C and
o
F.
Coarse Resolution. Use the OK button to toggle ON (blue dot) and
OFF. This function is for Voltage function only. The range and resolution
for the Voltage function will change as follows when Coarse Resolution is enabled:
Содержание DM284
Страница 1: ...QUICK START GUIDE MULTIMETER MODE ONLY FLIR MODEL DM284 MULTIMETER MODE QUICK GUIDE ...
Страница 7: ...FLIR DM284 DMM QUICK START GUIDE Document Identifier DM284 QS_DMM en US_AC MEASUREMENTS ...
Страница 8: ...FLIR DM284 DMM QUICK START GUIDE Document Identifier DM284 QS_DMM en US_AC ...
Страница 9: ...FLIR DM284 DMM QUICK START GUIDE Document Identifier DM284 QS_DMM en US_AC CLASSIC DIODE MODE ...