FLIR DM284 Скачать руководство пользователя страница 10

FLIR DM284 – DMM QUICK START GUIDE                                                    Document Identifier: DM284-QS_DMM-en-US_AC 

 

 

 

Corporate Headquarters 
FLIR Systems, Inc. 
2770 SW Parkway Avenue 
Wilsonville, OR 97070 USA 
Telephone: +1 503-498-3547 
 
Customer Support 
Technical Support Website    

http://support.flir.com 

Technical Support Email  

 

[email protected] 

Service and Repair Email 

 

[email protected] 

Customer Support Telephone  

+1 855-499-3662 option 3 (toll free) 

 

Certificate of Conformity and ISO-9001 Quality Management System 

 

FLIR Commercial Systems, Inc., an ISO 9001 certified company, hereby certify that our instruments meet or 
exceed the specifications stated in the user manuals.    

This instrument was produced under the stringent guidelines of FLIR Commercial System’s certified ISO 9001 
Quality Management System from design to delivery. All instruments are calibrated and inspected to meet the 
stated specifications. 

FLIR Commercial Systems, Inc. inspects its incoming shipments using an approved sampling plan with an 
Acceptable Quality Level (AQL). All incoming inspections are performed using test equipment that is traceable 
to National Standards.  Our ISO 9001 Quality Management System extends to aftermarket support where 
tested quality procedures are applied to customer support, service, calibration and repair processes. 

This instrument will provide years of reliable service when used in accordance with the instructions provided 
in the User Manual.  To have this device certified please contact your local service center.  

Quality Assurance Management 

 

Publication Identification No.:  DM284-QS_DMM 
Release version: 

 

AC 

Release Date:   

 

2017 January 

Language: 

 

 

en-US 

 

Translations of User Manuals and Quick Starts are available at the support.flir.com web site (download tab).

 

 

Copyright © 2016-2017 FLIR Systems, Inc. 

All rights reserved including the right of reproduction in whole or in part in any form. 

www.flir.com 

 

Содержание DM284

Страница 1: ...QUICK START GUIDE MULTIMETER MODE ONLY FLIR MODEL DM284 MULTIMETER MODE QUICK GUIDE ...

Страница 2: ...nput Jack 11 Positive Probe Input Jack for all inputs except A and mA 12 Display Hold H button 13 Cancel Return Button 14 IGMTM Button Battery compartment tilt stand tripod mount and test lead holder mounts on back of meter FUNCTION SWITCH POSITIONS Detect AC voltage through the non contact sensor at the top of the meter Measure voltage through low impedance loaded probe inputs Meter is switched O...

Страница 3: ...normal mode Press to enter Hold mode display hold or auto hold as selected in the Multimeter Settings Menu Press to enable disable the work light DISPLAY SYMBOLS Low Impedance mode Auto power off function enabled Measured voltage is 30 VAC DC AC current or voltage Non Contact Voltage detector DC current or voltage Battery voltage status Flex Clamp Direct Input MAX Maximum reading Continuity functi...

Страница 4: ...ds prior to entering APO mode the meter beeps at this point press any button or turn the Rotary Switch to reset the APO timer MENU SYSTEM Press OK to open the main menu Use the navigation arrows to step through the menu icons From left to right as shown below they are Image Mode Thermal Settings VFD Advanced Menu and Multimeter Settings Press OK to open a menu item or to set an option ON or OFF Wh...

Страница 5: ... 4 The primary display will show the difference between the measured value and the stored reference 5 Press OK at this icon to switch the Relative mode OFF PEAK MAX and PEAK MIN ACV and ACA only The meter captures and displays positive negative peaks and updates only when a higher lower value is registered 1 Access the Peak mode P in the Advanced menu 2 Use the up down navigation buttons to toggle...

Страница 6: ...ading and any new reading is 50 digits The Auto hold function will capture a reading if the reading is greater than the trigger level 1 of full scale range for Voltage Current Capacitance For Resistance Diode Temperature the trigger is automatic as long as OL is not displayed To enter exit Auto hold mode press the H button FREQUENCY MEASURMENTS ACV and ACA only The frequency is displayed above the...

Страница 7: ...FLIR DM284 DMM QUICK START GUIDE Document Identifier DM284 QS_DMM en US_AC MEASUREMENTS ...

Страница 8: ...FLIR DM284 DMM QUICK START GUIDE Document Identifier DM284 QS_DMM en US_AC ...

Страница 9: ...FLIR DM284 DMM QUICK START GUIDE Document Identifier DM284 QS_DMM en US_AC CLASSIC DIODE MODE ...

Страница 10: ...ted to meet the stated specifications FLIR Commercial Systems Inc inspects its incoming shipments using an approved sampling plan with an Acceptable Quality Level AQL All incoming inspections are performed using test equipment that is traceable to National Standards Our ISO 9001 Quality Management System extends to aftermarket support where tested quality procedures are applied to customer support...

Отзывы: