FLIR DM284 – DMM QUICK START GUIDE                                                    Document Identifier: DM284-QS_DMM-en-US_AC 

MODE BUTTON OPERATION 

Switch Position 

MODE button sequence of operation 

   

 

AC → DC → Hz → °F or °C 

 

ACV → HZ 

 

Resistance → Continuity → Capacitance → Diode 

 

AC → DC 

 

AC → DC → HZ 

METER POWER 

Set the function switch to any position to switch the meter ON. If LO BATT is displayed, if one of the Low 

Battery screens appear (below), if the battery icon appears low  , or if the meter does not power on, 
replace the four (4) 1.5V ‘AAA’ batteries in the rear compartment. The optional TA04 Rechargeable Li-
Polymer Battery system is available if battery recharging, rather than replacement, is preferred. 

 

                  

 

The meter enters sleep mode after 10 minutes (default). The time can be set from 1 ~ 10 minutes (or OFF) in 
the Multimeter Settings menu. 20 seconds prior to entering APO mode, the meter beeps; at this point, press 
any button or turn the Rotary Switch to reset the APO timer. 

MENU SYSTEM 

 

Press OK to open the main menu, Use the navigation arrows to step through the menu icons. From left to 
right, as shown below, they are: Image Mode, Thermal Settings, VFD, Advanced Menu, and Multimeter 
Settings. 

 

 

Press OK to open a menu item or to set an option ON or OFF. When an option is switched ON, a blue dot 
will appear next to the icon. The navigation arrows are sometimes used to select an option. 

 

Use the Cancel/Return button 

 to exit menu levels and to return to the normal display mode. 

AUTO/MANUAL RANGE 

In Auto range mode, the meter automatically selects the most appropriate measurement scale. In Manual 
range mode, the desired range (scale) can be adjusted by the user. Auto range mode is the default mode of 
operation. When a new function is selected with the function switch, the starting mode is Auto range and 
the   indicator is displayed. 

Содержание DM284

Страница 1: ...QUICK START GUIDE MULTIMETER MODE ONLY FLIR MODEL DM284 MULTIMETER MODE QUICK GUIDE ...

Страница 2: ...nput Jack 11 Positive Probe Input Jack for all inputs except A and mA 12 Display Hold H button 13 Cancel Return Button 14 IGMTM Button Battery compartment tilt stand tripod mount and test lead holder mounts on back of meter FUNCTION SWITCH POSITIONS Detect AC voltage through the non contact sensor at the top of the meter Measure voltage through low impedance loaded probe inputs Meter is switched O...

Страница 3: ...normal mode Press to enter Hold mode display hold or auto hold as selected in the Multimeter Settings Menu Press to enable disable the work light DISPLAY SYMBOLS Low Impedance mode Auto power off function enabled Measured voltage is 30 VAC DC AC current or voltage Non Contact Voltage detector DC current or voltage Battery voltage status Flex Clamp Direct Input MAX Maximum reading Continuity functi...

Страница 4: ...ds prior to entering APO mode the meter beeps at this point press any button or turn the Rotary Switch to reset the APO timer MENU SYSTEM Press OK to open the main menu Use the navigation arrows to step through the menu icons From left to right as shown below they are Image Mode Thermal Settings VFD Advanced Menu and Multimeter Settings Press OK to open a menu item or to set an option ON or OFF Wh...

Страница 5: ... 4 The primary display will show the difference between the measured value and the stored reference 5 Press OK at this icon to switch the Relative mode OFF PEAK MAX and PEAK MIN ACV and ACA only The meter captures and displays positive negative peaks and updates only when a higher lower value is registered 1 Access the Peak mode P in the Advanced menu 2 Use the up down navigation buttons to toggle...

Страница 6: ...ading and any new reading is 50 digits The Auto hold function will capture a reading if the reading is greater than the trigger level 1 of full scale range for Voltage Current Capacitance For Resistance Diode Temperature the trigger is automatic as long as OL is not displayed To enter exit Auto hold mode press the H button FREQUENCY MEASURMENTS ACV and ACA only The frequency is displayed above the...

Страница 7: ...FLIR DM284 DMM QUICK START GUIDE Document Identifier DM284 QS_DMM en US_AC MEASUREMENTS ...

Страница 8: ...FLIR DM284 DMM QUICK START GUIDE Document Identifier DM284 QS_DMM en US_AC ...

Страница 9: ...FLIR DM284 DMM QUICK START GUIDE Document Identifier DM284 QS_DMM en US_AC CLASSIC DIODE MODE ...

Страница 10: ...ted to meet the stated specifications FLIR Commercial Systems Inc inspects its incoming shipments using an approved sampling plan with an Acceptable Quality Level AQL All incoming inspections are performed using test equipment that is traceable to National Standards Our ISO 9001 Quality Management System extends to aftermarket support where tested quality procedures are applied to customer support...

Отзывы: