FLIR DM284 Скачать руководство пользователя страница 1

             

QUICK START GUIDE

 

MULTIMETER MODE ONLY 

 

FLIR MODEL DM284 

MULTIMETER MODE QUICK GUIDE

 

 

         

                

Содержание DM284

Страница 1: ...QUICK START GUIDE MULTIMETER MODE ONLY FLIR MODEL DM284 MULTIMETER MODE QUICK GUIDE ...

Страница 2: ...nput Jack 11 Positive Probe Input Jack for all inputs except A and mA 12 Display Hold H button 13 Cancel Return Button 14 IGMTM Button Battery compartment tilt stand tripod mount and test lead holder mounts on back of meter FUNCTION SWITCH POSITIONS Detect AC voltage through the non contact sensor at the top of the meter Measure voltage through low impedance loaded probe inputs Meter is switched O...

Страница 3: ...normal mode Press to enter Hold mode display hold or auto hold as selected in the Multimeter Settings Menu Press to enable disable the work light DISPLAY SYMBOLS Low Impedance mode Auto power off function enabled Measured voltage is 30 VAC DC AC current or voltage Non Contact Voltage detector DC current or voltage Battery voltage status Flex Clamp Direct Input MAX Maximum reading Continuity functi...

Страница 4: ...ds prior to entering APO mode the meter beeps at this point press any button or turn the Rotary Switch to reset the APO timer MENU SYSTEM Press OK to open the main menu Use the navigation arrows to step through the menu icons From left to right as shown below they are Image Mode Thermal Settings VFD Advanced Menu and Multimeter Settings Press OK to open a menu item or to set an option ON or OFF Wh...

Страница 5: ... 4 The primary display will show the difference between the measured value and the stored reference 5 Press OK at this icon to switch the Relative mode OFF PEAK MAX and PEAK MIN ACV and ACA only The meter captures and displays positive negative peaks and updates only when a higher lower value is registered 1 Access the Peak mode P in the Advanced menu 2 Use the up down navigation buttons to toggle...

Страница 6: ...ading and any new reading is 50 digits The Auto hold function will capture a reading if the reading is greater than the trigger level 1 of full scale range for Voltage Current Capacitance For Resistance Diode Temperature the trigger is automatic as long as OL is not displayed To enter exit Auto hold mode press the H button FREQUENCY MEASURMENTS ACV and ACA only The frequency is displayed above the...

Страница 7: ...FLIR DM284 DMM QUICK START GUIDE Document Identifier DM284 QS_DMM en US_AC MEASUREMENTS ...

Страница 8: ...FLIR DM284 DMM QUICK START GUIDE Document Identifier DM284 QS_DMM en US_AC ...

Страница 9: ...FLIR DM284 DMM QUICK START GUIDE Document Identifier DM284 QS_DMM en US_AC CLASSIC DIODE MODE ...

Страница 10: ...ted to meet the stated specifications FLIR Commercial Systems Inc inspects its incoming shipments using an approved sampling plan with an Acceptable Quality Level AQL All incoming inspections are performed using test equipment that is traceable to National Standards Our ISO 9001 Quality Management System extends to aftermarket support where tested quality procedures are applied to customer support...