CABLE ASSIGNEMENT 

 
 

 

 

 

 
 
* Note that RS-485 signals are deactivated internally to avoid picking up noise. 
To activate RS485/422 you have to open the compartment on the back using Torx TX-
25 for the M4x10 screws, connect the Black and the Violet leads to terminals A+ and 
B- respectively 
 
 

3. Operation Notes 

INSTALLATION NOTES 

To comply with various safety and conformance rulings, the system must be properly 
grounded.  The  Scoreboard  itself  needs  to  be  connected  to  safety  earth,  and  the 
connector should be firmly mated and fixed by use of fixing screws. 
When power is applied, the display should respond by a sequence of control messages 
(see „Normal Behaviour“). After the short start-up formality, display is blanked. If this 
sequence is missing, check power source and connections. The voltage present at the 
pins on the Scoreboard D-sub should be stable between 8 and 28 Vdc. 

Pink 

+V DC  External Power  

Grey 

GND 

External Power supply – 

*Black 

A+ 

RS-485/422 Transciever 

*Violet 

B- 

RS-485/422 Transciever 

White 

TTY+  Input positive 20 mA 

Brown 

TTY- 

Input negative 20 mA 

Blue 

RxD 

RS232 Input from TxD of Host 

Red/Blue 

RxD 

GND 

RS232 Signal Ground 
(Short it with GREY) 

Red 

TxD 

RS232 Output to RxD of Host 
(Not needed for normal use) 

Green 

+O 

+ Output 
(Not needed for normal use) 

Yellow 

-O 

- Output 
(Short it with GREY) 

Содержание FRD-100 BL

Страница 1: ...splay MANUAL Release 20 07 2007 This manual was created with special care on the technical content and the correct verbalisation However as a matter of principle Flintec GmbH will not take responsibil...

Страница 2: ...aintained according to the applicable technical instructions drawings and specifications no hazard exists in the normal and intended use of these products General Safety Guidelines The following gener...

Страница 3: ...h x d w o connector Size inc bracket 550 mm x 180 mm x 58 mm w x h x d w o connector Materials Stainless Steel 316 Protection IP 65 Weight 4 5 kg net Display Dimensions ELECTRONICS Interface field sel...

Страница 4: ...by use of fixing screws When power is applied the display should respond by a sequence of control messages see Normal Behaviour After the short start up formality display is blanked If this sequence...

Страница 5: ...the indicator If the screen is still empty after 5 minutes please deactivate everything check again the cables and the indicator interface settings and restart everything Note that reducing the voltag...

Страница 6: ...onformity Flintec GmbH Bemannsbruch 9 D 74909 Meckesheim The following named product FRD 100 BL Display is conform to the following european directives and standards EN55011 EN50082 Part 1 and 2 and C...

Страница 7: ...the right weigh FRD 100 BL Manual page 7 of 7 4 SERVICE AND CONTACT INFORMATION Flintec GmbH Bemannsbruch 9 74909 Meckesheim Germany Tel 49 6226 9240 0 Fax 49 6226 9240 99 http www flintec com...

Отзывы: