NORMAL BEHAVIOUR 

When power is applied, the Scoreboard will go through a sequence of initialisation. By 
carefully looking at the display, you will be presented the following data: 
 

888888 

all segments are on, then off to verify correct operations 

08.25 

is the firmware version 

A.00 

is the address of the display (normally set to 00 if disabled) 

C:9600 

indicates the current baud rate setting 

P: 20 

Protocol number or other identification 

 
After  initialisation,  the  Scoreboard  will  blank  with  all  decimal  points  activated.  This  is 
the default 'waiting screen' indicating that it is awaiting a valid message. 
 
The Display is set to “Autosearch” by standard. It will try to detect the connection and 
data  protocol  settings  by  itself.  This  detection  is  shown  on  the  screen  and  can  take 
some  minutes.  After  the  settings  were  found  the  display  should  show  the  incoming 
data on screen. (e.g. the weight sent out by the indicator) 
If the screen is still empty after 5 minutes, please deactivate everything, check again 
the cables and the indicator interface settings and restart everything. 
 
Note  that  reducing  the  voltage  supplied  below  20V  will  turn  off  backlight  and  reduce 
current consumption. The operation will otherwise be as normal. 

STANDARD DATA PROTOCOL DESCRIPTION 

As a serial display, the message format handled is based on the parameter setting that 
defines valid and essential data. The data displayed is replaced each time a valid new 
message  is  received.  The  timeout  function  may  auto  blank  the  display  after  a  preset 
number of seconds. 
 
There  are  a  lot  of  predefined  protocols  stored  in  the  Display.  The  autosearch  will 
automatically set the correct one (if existing) to fit the incoming Data 
 
The following text only describes the factory default protocol. 
 

Default Protocol 

<STX>data<CR> 

Where <STX>=ASCII 02d, <CR>=ASCII 13d. Data includes minus sign (-), decimal 
point (represented by '.' or',') and leading blanks or zeros. 
 

Addressing Control 

<SOH> AA <STX> 

Will select display AA (00 to 99). 00 will broadcast to all connected displays. 
Addressing is used relatively seldom

.

 

 

Содержание FRD-100 BL

Страница 1: ...splay MANUAL Release 20 07 2007 This manual was created with special care on the technical content and the correct verbalisation However as a matter of principle Flintec GmbH will not take responsibil...

Страница 2: ...aintained according to the applicable technical instructions drawings and specifications no hazard exists in the normal and intended use of these products General Safety Guidelines The following gener...

Страница 3: ...h x d w o connector Size inc bracket 550 mm x 180 mm x 58 mm w x h x d w o connector Materials Stainless Steel 316 Protection IP 65 Weight 4 5 kg net Display Dimensions ELECTRONICS Interface field sel...

Страница 4: ...by use of fixing screws When power is applied the display should respond by a sequence of control messages see Normal Behaviour After the short start up formality display is blanked If this sequence...

Страница 5: ...the indicator If the screen is still empty after 5 minutes please deactivate everything check again the cables and the indicator interface settings and restart everything Note that reducing the voltag...

Страница 6: ...onformity Flintec GmbH Bemannsbruch 9 D 74909 Meckesheim The following named product FRD 100 BL Display is conform to the following european directives and standards EN55011 EN50082 Part 1 and 2 and C...

Страница 7: ...the right weigh FRD 100 BL Manual page 7 of 7 4 SERVICE AND CONTACT INFORMATION Flintec GmbH Bemannsbruch 9 74909 Meckesheim Germany Tel 49 6226 9240 0 Fax 49 6226 9240 99 http www flintec com...

Отзывы: