64
USER MANUAL - WebdynEasy LoRaWAN
Version 0.10
/lorawan/packet_forwarder/public
Type of LoRaWAN public network
preamble (public: 0x34, private:
0x12)
(do not modify, only used for
testing)
Boolean (true, false)
true
/lorawan/server/netid
LoRaWAN network identifier (see
LoRaWAN specification) If you
enter 0, when the hub reboots, it
will use its factory NetID.
Hexadecimal 3 bytes
Calculated
automatically from its
MAC address
/lorawan/server/adr/enable
Enable ADR
Boolean (true, false)
true
/lorawan/server/adr/margin_db
Margin in dB to calculate ADR
Integer (min 1 max 30)
5
/lorawan/server/adr/uplink_count
The number of uplinks needed
for ADR
Integer (min 1 max
65535)
20
/lorawan/server/udp_port
LoRaWAN server UDP port
Integer (min 1 max
65535)
1700
/lorawan/server/backup_interval
Automatic configuration backup
interval with the Fcntup and
Fcntdown counters. (in seconds)
Whole number (min 1
max 4,294,967,295)
86400
/lorawan/server/modules/module/
List of LoRaWAN modules
/lorawan/server/modules/module/deveui
Unique sensor identifier (EUI64)
Hexadecimal 8 bytes
/lorawan/server/modules/module/appkey
Encryption key used by the
network to derive the session
keys.
Hexadecimal 16 bytes
/lorawan/server/modules/module/devaddr
Sensor address
Hexadecimal 4 bytes
/lorawan/server/modules/module/appskey
Encryption key between the
sensor and the application server
Hexadecimal 16 bytes
/lorawan/server/modules/module/nwkskey
Encryption key between the
sensor and the LoRaWAN server
Hexadecimal 16 bytes
/lorawan/server/modules/module/fcntup
Uplink frame counter (to the
server)
Whole number (min 0
max 4,294,967,295)
/lorawan/server/modules/module/fcntdown
Downlink frame counter (to the
sensor)
Whole number (min 0
max 4,294,967,295)