7 Connection
UMFLUXUS_F7V4-6-2EN, 2017-10-01
53
7.1
Transducers
It is recommended to run the cables from the measuring point to the transmitter before connecting the transducers to
avoid load on the connectors.
For the connection of the transducer cable to the transmitter see section 7.1.1 (FLUXUS F704, FLUXUS F705, FLUXUS
F706).
For the connection of the extension cable to the transmitter see section 7.1.2.
For the connection of the transducer cable to the junction box see section 7.1.3.
For the connection of the extension cable to the junction box see section 7.1.4.
7.1.1
Connection of the Transducer Cable to the Transmitter (FLUXUS F704, F705, F706)
For the connection of the transducer cable with SMB connectors (connection system TS, direct connection) see section
7.1.1.1.
For the connection of the transducer cable with a plastic cable jacket and stripped cable ends (connection system TS, di-
rect connection) see section 7.1.1.2.
For the connection of the transducer cable with a stainless steel conduit and stripped cable ends (connection system TS,
direct connection) see section 7.1.1.3.
7.1.1.1
Transducer Cable with SMB Connectors
• Remove the left blind plug for the connection of the transducer cable (see Fig. 7.5 or Fig. 7.6).
Note!
If transducers are replaced or added, the sensor module also has to be replaced or added (see sec-
tion 7.7).
Attention!
Observe the "Safety Instructions for the Use in Explosive Atmosphere" (see document SIFLUXUS).
Attention!
The degree of protection of the transmitter is ensured only if the cable glands are firmly tightened and
the housing is tightly screwed.
Attention!
Observe the "Safety Instructions for the Use in Explosive Atmosphere" (see document SIFLUXUS).
Fig. 7.5: Connection of the transducer cable with SMB connectors
to the transmitter FLUXUS F704
AVS
AV
AGN ARS AR
BVS
BV
BGN BRS BR
SA1 SA2 SA3 SA4
SB1 SB2 SB3 SB4
T1a T1b S2 T2a
T3a T3b S4 T4a
T2b
T4b
T1A T1B S1 T2A
T3A T3B S3 T4A
T2B
T4B
A+ B- P1+ P2+
P4+ P5a P6a P7a
P3+
101 103 P1- P2-
P4- P5b P6b P7b
P3-
PE N(-) L(+)
SMB connector
equipotential
bonding terminal
(FLUXUS F704**-A2)
transducers
measuring channel B
transducers
measuring channel A