6 Installation
6.2 Transducers
FLUXUS F501
2020-06-30, UMFLUXUS_F501V1-3EN
42
Step 1: Dismounting of the transducer mounting fixture Variofix C
• Disassemble the transducer mounting fixture Variofix C.
In order to remove the cover from the rail, bend the outer sides of the cover outwards, see Fig. 6.33.
In order to remove the spring clip from the rail, slide it over the indentation on the rail and lift it off, see Fig. 6.34.
Step 2: Mounting the rail
• Select the installation instructions according to the supplied clasp:
Mounting of the rail without a clasp
• Cut the tension strap to length (pipe circumf at least 120 mm).
Fig. 6.33: Removal of the cover
Fig. 6.34: Dismounting of the transducer mounting fixture Variofix C
1 – cover
2 – tensioning screw
3 – spring clip
4 – indentation
5 – spacing element
6 – rail
7 – tension strap clamp
Caution!
The edge of the tension strap is very sharp.
Risk of injury!
→ Debur sharp edges.
→ Wear the required personal protective equipment. Observe the applicable rules.
1
2
3
4
5
6
7