18 Settings
FLUXUS F501
18.1 Dialogs and menus
121
UMFLUXUS_F501V1-3EN, 2020-06-30
18
Settings
18.1
Dialogs and menus
• Select the menu item
Special Funct.\SYSTEM settings\Dialogs/Menus
.
• Press ENTER.
18.1.1
Pipe circumference
• Select
on
if the pipe circumference is to be entered instead of the pipe diameter in the program branch
Parameter
.
• Press ENTER.
If
on
is selected for
Pipe Circumfer.
, the outer pipe diameter will still be requested in the program branch
Parameter
.
• In order to select the menu item
Pipe Circumfer.
, enter zero.
• Press ENTER.
The value displayed in
Pipe Circumfer.
is calculated on the basis of the last displayed value of the outer pipe diameter.
Example: 100 mm
.
π = 314.2 mm
• Enter the pipe circumference. The limits for the pipe circumference are calculated on the basis of the limits for the outer
pipe diameter.
• Press ENTER.
During the next scroll through the program branch
Parameter
, the outer pipe diameter that corresponds to the entered
pipe circumference will be displayed.
Example: 180 mm : π = 57.3 mm
18.1.2
Measuring point number
• Select (
1234
) if the measuring point is to be identified only by numbers, point and hyphen.
• Select (
↑↓← →
) if the measuring point is to be designated with ASCII characters.
• Press ENTER.
Special Funct.\SYSTEM settings\Dialogs/Menus
Notice!
The settings will be stored at the end of the dialog. If the menu item is quit by pressing key BRK, the changes will not
be stored.
Special Funct.\...\Dialogs/Menus\Pipe Circumfer.
Special Funct.\...\Dialogs/Menus\Pipe Circumfer.\Outer Diameter
Notice!
The edition of the pipe circumference is only temporarily. When the transmitter switches back to the display of the
pipe circumference (internal recalculation), slight rounding errors may occur.
Example
entered pipe circumference: 100 mm
displayed outer pipe diameter: 31.8 mm
When the transmitter switches back to the display of the pipe circumference, 99.9 mm will be displayed.
Special Funct.\...\Dialogs/Menus\Meas.Point No.:
Содержание FLUXUS F501
Страница 1: ...FLUXUS F501 UMFLUXUS_F501V1 3EN Operating instruction...
Страница 6: ...Table of contents FLUXUS F501 2020 06 30 UMFLUXUSF501V1 3EN 6...
Страница 143: ...Annex FLUXUS F501 D Conformity declarations 143 UMFLUXUS_F501V1 3EN 2020 06 30 D Conformity declarations...
Страница 144: ...Annex D Conformity declarations FLUXUS F501 2020 06 30 UMFLUXUS_F501V1 3EN 144...
Страница 145: ......
Страница 146: ......