Operators and Reference Manual
MC12
MC12 OM RM EN 74-111-132 v1.03.doc
Ver. 1.03
Page 25 of 47
The system will not report that the filling has been completed until all connected drives have
completed their respective fills. After this, Functions 8, 10 and 11 for drive 0 will be updated
by the total of all connected drives.
3 - Serial (S)
Serial filling is used to boost the overall capacity in a semi or fully automated system by using
each drive to fill part of the total volume.
Similar to parallel filling, drive 0 is used for programming, with the exception of Function 2 for
tube diameter.
For the programming of tube diameter the individual drive is selected via Function 41 and the
tube diameter is entered under Function 2. In this way, the last drive may for instance fill a
smaller part of the total volume than the other drives in the system. This is done by applying
a smaller tube in the last drive.
When all drives have been programmed, the MC12 will automatically calculate which part of
the total volume the individual drives should fill, so that they are completed simultaneously.
This gives the best capacity.
Calibration is also carried out in drive 0, as the system perceives the whole system as one
single drive.
Functions 8 and 10 will be calculated on the basis of completed fills from the last drive and
Function 11 will be calculated on the basis of all drives.
6.7.31. Function 41 - Select filler (drive)
If several pumps are connected, this function is used for selecting the number of the filler to
be shown on the display and to be controlled via the keyboard.
Function 41 selects the drive to be programmed and shown on the display. The current drive
number is always shown in the top right hand corner of the display.
Press: <4>+<1>+<ENT>, and display shows: “ENTER DRIVE NO.:”
The drive number required for the new drive can now be entered, followed by <ENT>. The
system will then show the new current drive in the display indicating the new number in the
top right hand corner. If a drive number is entered which is not connected, the system will
correct the number to the lowest number representing a connected drive.
Drive 0
Drive 0 does not exist physically. Drive 0 is used as the current drive when the system works
in the parallel or serial mode.
Drive 0 in individual mode
Drive 0 is not used in this mode as all drives work with different parameters and applications.
Drive 0 in parallel mode
The following parameters are identical for all drives in the parallel mode and they are
consequently programmed in drive 0: