![Flexicon 61-110-014 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/flexicon/61-110-014/61-110-014_operators-manual_2304652022.webp)
Operators and Reference Manual
MC12
MC12 OM RM EN 74-111-132 v1.03.doc
Ver. 1.03
Page 22 of 47
6.7.25. Function 31 - Save program
It is possible to save up to 100 sets of parameters in the memory, i.e. one drive will have 100
programs available, and with two drives, each will have 50 programs available.
If a particular set of parameters is used frequently, it is a good idea to store the settings in
order to allow their easy retrieval as a complete filling program. This also ensures that exactly
the same parameters are used each time, reducing the risk of programming errors.
A stored program contains the following function parameters:
The individual drives: F1 - F2 - F3 - F4 - F5 - F9 - F18 - F19 – and the last calibration value.
It is important that all parameters are entered and that these parameters are checked before
saving the program saved via Function 31.
The system will always suggest the first available number in a range between 1 and 100.
If this number is to be accepted as the program number, press <ENT>, and all parameters
will be saved under this program number.
If another number is required, enter the number chosen, and if this number is free, the
program is saved by pressing <ENT>.
If the number is occupied by a program already saved, the system will ask:
“OVERWRITE PGM. (Y/N)”
If <Y> is pressed, the old program is deleted and the new program is saved with this number.
If <N> is pressed, the system will go back to the position from which a new program number
can be selected.
Select a new program number and press <ENT> to confirm this new number.
The old program saved under the number originally suggested will be kept and the program
will be saved under the new number.
If program number 0 is selected, the function is left without saving the program.