11
4.2b H-Type
©
Primary Cleaner with V-Tips
Section 4 – Installation Instructions
7. Position the pole. Rotate pole upward to bring tips into contact with
head pulley (Fig. 7). Centre the tips across the belt. While applying
light pressure on the centre tip, shift loosened bearing mount until
tips are contacting belt evenly across full width. Lock cleaner into
this position by tightening bearing mount bolts.
6. Install the pole. Remove the two bearing mount bolts from one of
the bearing mounts (Fig. 6). (If chute mount, remove from the side
with access hole.) Slide the pole across the pulley and into the bearing
mount on other side and allow tips to hang down. Install the removed
bearing mount on the pole and reattach to the mounting bracket.
NOTE: Do not tighten; leave finger tight.
Fig. 7
4.3 H-Type
©
Primary Cleaner with V-Tips - Bolt Tensioner
Open Head Mounting (cont.)
Bearing
Mount Bolts
Fig. 6
Slide
1. Install the pole. Remove the two bearing block bolts from
one of the bearing blocks (Fig. 1). (If chute mount, remove
from the side with access hole.) Slide the pole across the
pulley and into the bearing block on other side and allow tips
to hang down. Install the removed bearing block on the pole
and reattach to the mounting bracket. Do not tighten; leave
finger tight.
2. Position the pole. Rotate pole upward to bring tips into
contact with head pulley (Fig. 2). Centre the tips across
the belt. While applying light pressure on the centre tip,
shift loosened bearing block until tips are contacting belt
evenly across full width. Lock cleaner into this position by
tightening bearing mount bolts.
Fig. 2
Fig. 1
BEARING
BLOCK
BOLTS
Slide