7.4 Blade Replacement Instructions
Section 7 – Maintenance
Tools Needed
• Tape measure
• (2) 38mm wrenches or crescent wrenches
• (1) 17mm wrench
• Wire brush (for cleaning pole)
• Small putty knife (for cleaning pole)
1. Remove the tension. Loosen the adjusting nuts on the mounting
bracket/PCST assembly to remove tension from the arm (Fig. 1). This
releases the tension of the blade on the belt.
2. Remove the worn tips. Remove the nuts on each tip and remove the
tips from the cushion (Fig. 2). Clean all fugitive material from the pole.
NOTE: If tips are hard to remove use a screwdriver or hammer to
loosen it and then remove.
Physically lock out and tag the conveyor at the power source
before you begin cleaner installation.