3 . 1 - R e l a y S p e c i f i c a t i o n s
The Q5 Relays are subject to environmental de-rating as detailed below.
-4
5
to
4
0°
C
41
to
5
5°
C
55
to
1
00
° C
8 Amps
6 Amps
4 Amps
2 Amps
0 Amps
10
0
m
S
10
S
30
S
50 Amps
40 Amps
30 Amps
20 Amps
10 Amps
0 Amps
Max on time in 1 minutes period.
Red - under 30 Volts.
Blue - 30 to 60 Volts.
Switch Impedance: 8 mOhms (Not including fuse)
Max Open Voltage: 70 VDC
Power Consumption: 2 mW in closed state
Isolation Level: +/- 125 V (Channel to Channel or
Channel to Q5 Ground)
Max Surge Rating: 250 A transient pulsed; tp
≤
10 µs
Max Current Sensing: 5 A (PRO ONLY)
Contains fly-back suppression for switching inductive
loads such as relays, motors, etc.(up to 140 mJ (Max
250 A Peak Current)
Technical Specifications
Switched Load
Power Source
Power Distributor Bus
No. ACC-Q5-DIST15A
For systems using a single voltage we offer a distribution bus to cut down on
the required wiring. When using the distributor each channel acts as a power
source rather than an isolated switch. The max combined load across all
channels must not exceed 15 A. No software configuration is required for this
hardware accessory.