![Flex-Pro Norprene A3 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/flex-pro/norprene-a3/norprene-a3_operating-manual_2304440021.webp)
Page 21
9.6
Manual Cycle Adjust (repeating cycle timer)
Used to run at a pre-selected motor speed for a specified run time. This cycle
will repeat itself using a repeating cycle timer.
Default settings:
100% motor speed for 1.5 seconds
Repeating cycle timer = 4 seconds
Press SELECT RUN MODE button until
Manual Cycle Adjust
is displayed in
the top line of the display.
To configure the pump, navigate to
Manual Cycle Adjustment
menu by using
short-cut method described at beginning of section, or by pressing MENU
button, then selecting Input Setup, Input Modes, and then
Cycle Adjustment
.
Press UP or DOWN arrow to scroll through 0 - 9 on selected digit.
Press RIGHT arrow to scroll over to next digit to right. If you pass your desired
digit, you can easily scroll back by continuously pressing RIGHT button.
Press ENTER to save changes.
Continue this process until all three screens have been configured.
If you used short-cut to enter Manual Cycle Adjustment setup, then just press
and hold Select Run Mode button until Run Mode screen is displayed.
If you used Menu button to navigate to Cycle Adjustment setup, you must
navigate back out of menu structure. To do this you must select <-Esc at bottom
of every screen menu until you see Run Mode screen displayed.
- Cycle Adjust.
Input Duty On-Time:
Run-Time per cycle.
01.5
0
- Cycle Adjust.
Input Pump Speed:
Set % pump speed.
00.0%
0
- Cycle Adjust.
Total Cycle Time:
Repeating Timer.
04.0
0
Press ENTER to set.
Max = 999.9 Seconds
Max = 999.9 seconds
Cycle (SEC.):
4.0
On Time (SEC.) 1.5
Manual Cycle Adjust
In Manual Cycle Adjust mode, you can view
current settings by pressing RIGHT arrow (see
screen shot). RIGHT arrow is a convenient
way to scroll through multiple read-only
screens during normal operating mode of
pump.
Tip!
- Screen Shot -
1.5 Sec. On-Time
(Chemical Feed)
Injection Point
Graphical representation of Manual Cycle Adjust injection characteristics.
Note:
Your chemical or solution is mixed in fluid. This image is only illustrating feed characteristics.
4 Second Total Cycle Time
(Repeating Timer)
4 Second Total Cycle Time
(Repeating Timer)
1.5 Sec. On-Time
(Chemical Feed)
Flex-Pro
Содержание Norprene A3
Страница 32: ...Page 32 This Page Blank Flex Pro...
Страница 33: ...Page 33 This Page Blank Flex Pro...
Страница 34: ...Page 34 This Page Blank Flex Pro...