background image

Installation, Operation & Maintenance Guide

Style 79

BEFORE STARTING THE EQUIPMENT

1

. Ensure the pump shaft is properly aligned at

the coupling with the motor.

2

. Check that all gland plate bolts and all screws

are securely fastened.

3

. Once the pump is reassembled, turn the shaft

by hand if possible to check for free rotation, if
not, recheck installation.

4

. Verify that all plumbing and piping plans for the

seal are connected and configured according
to best practice.

5

. Flood the pump, vent all air from the seal

chamber, and again check seal for leakage.
Ensure the product is not leaking into the seal
support system by noting changes in liquid
level and buffer/barrier fluid pressure.

6

. Ensure all plumbing and venting for the seal

and seal support system are free of obstruction
and that the chamber is filled with liquid. Check
that all alarms connected to auxiliary systems
are properly functioning to alert personnel if
any issues arise.

Dry-running is a major cause for leakage
and/or failure of mechanical seals. It is
imperative that the seal chamber be
completely vented prior to startup and that
adequate lubrication is supplied to the seal.

7

. Start the pump per the pump manufacturer’s

recommendations, observe for proper
operation, and check for excessive heat at the
seal gland.

Check periodically during operation to
ensure that the seal is not overheating.

OPERATION & MAINTENANCE

If leakage is detected, it should be addressed as soon as possible to prevent hazards and protect personnel.
Leakage could come from a number of leak paths in the seal, or be caused by changes in the pump operation or
condition. Although seals should be inspected regularly for signs of leakage, a properly selected and functioning
mechanical seal will run for extended durations without need for extra attention and should not be disturbed
unnecessarily (i.e. shut down and disassembled without cause). Below is an inexhaustive list of possible causes
of leakage.

Primary Causes

• Worn seal faces

• Damaged O-rings

• Damaged springs

Secondary Causes

• Change in duty conditions

• Dry-running

• Worn bearings

• Increased vibration

It is important to periodically inspect and maintain flush systems, shaft alignment, and consistent duty
parameters to ensure the seal performs as designed. Often, there is a case of cause & effect with machinery
and processing issues upstream that can cause a seal to leak. Check for the root cause of leakage when
disassembling equipment for inspection or service.

Buffer/barrier fluids will break down over time or become contaminated with process leakage. Fluids should be
drained from the system as often as possible or during scheduled pump shutdowns. The reservoir and
tubing/piping should be flushed and filled with new, clean buffer/barrier fluid. It is important to clean the seal
support system after a seal failure; the cleaning fluid and procedure required will depend on the contamination in
the reservoir. Never re-use barrier fluid after a seal failure.

Page 6 of 7

Содержание Style 79

Страница 1: ...ERS REPAIR SERVICE 1 Jackson Street Rua Java s 441 443 1719 South Sonny Avenue Essex Junction VT 05452 Bom Retiro Sao Paulo Gonzales LA 70737 Brazil CEP 01130 010 TEL 802 878 8307 TEL 55 11 3736 7373...

Страница 2: ...maintenance must only be carried out by qualified personnel who have thoroughly read all instructions 3 The seal must only be used for its intended application Flex A Seal cannot be held liable for u...

Страница 3: ...er face of rust burrs grit sharp edges and set screw damage using fine emery cloth Wipe clean Avoid making flat spots or reducing the shaft diameter 4 If the pump is equipped with a shaft sleeve verif...

Страница 4: ...0 0015 0 003 in Fig 3 Radial bearing fit 0 002 0 003 in Fig 4 Bearing frame perpendicularity 0 0005 in in Fig 5 Axial shaft movement end play 0 005 in Fig 6 Seal chamber bore concentricity 0 005 in Fi...

Страница 5: ...facing but clear of the seal chamber 6 Reassemble the pump as described by the pump OEM 7 If the gland is equipped with a gland gasket lubricate gland bolts and bolt the gland to the seal chamber usin...

Страница 6: ...ection on the seal gland Figure 8 Piping should slope continuously upwards 1 2 in ft 40 mm m minimum with no relative high points that would result in trapped air in the tubing For shafts smaller than...

Страница 7: ...E If leakage is detected it should be addressed as soon as possible to prevent hazards and protect personnel Leakage could come from a number of leak paths in the seal or be caused by changes in the p...

Страница 8: ...luids contained in the pump drain and decontaminate before opening the housing for seal service 1 Ensure all fluid has been drained and vented from both the pump and seal support system Equipment shou...