 SAFETY PRECAUTIONS

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.

     Never plug in nor remove the  power supply  plug
     with wet hands, as   doing so  may cause electric
    shock.

     When unplugging   the  power   supply cord, be sure
     to grasp the   power  supply   plug; never  pull on the
    cord  itself.  Operating   the  unit   with  a  damaged
    power  supply  cord  may  cause  a  fire  or  electric 
    shock.

     When moving the unit, be sure  to remove its power 
     supply cord   from the  wall   outlet.  Moving   the unit
     with the   power  cord   connected  to   the outlet may
     cause damage to the power cord,  resulting in fire or 
     electric shock. When   removing the power cord,  be
     sure to hold its plug to  pull.

  Do not block the ventilation slots in the unit's cover.
  Doing so may cause heat to build up inside the unit 
  and result in fire.

  Avoid installing the unit in humid or dusty locations,
  in locations exposed to the direct sunlight, near the 
  heaters, or in locations generating   sooty smoke or
  steam  as  doing  otherwise  may  result  in  fire  or 
  electric shock.

     Do not place heavy objects on the unit as this may
    

cause it to fall or break  which may result in personal

 

    

injury and/or property damage. In addition, the object

     itself may fall off and cause injury and/or damage.

    

Make sure that the volume  ontrol is set to minimum 

     position before power is switched on. Loud noise
     produced at high volume when power is switched 
     on can impair hearing.

     Do not operate the unit for an extended period of 
    

time with the sound distorting. This is an indication

     of a malfunction, which in turn can cause heat to
     generate and result in a fire.

    Contact  your  

  dealer as to the 

     cleaning. If dust is allowed to accumulate in the
     unit over a long period of time, a fire or damage
     to the unit may result.

FLEPCHER

  If dust accumulates on the power supply plug or in
  the   wall  AC  outlet, a fire may result. Clean it peri-
  

odically. In addition, insert the plug in the wall outlet 

  securely.

  Switch off  the power, and unplug the power supply
  plug from  the AC outlet for  safety purposes  when 
  cleaning or leaving the unit unused for 10  days or 
  more. Doing otherwise may cause a fire  or electric 
  shock.

Due to product upgrades, while some of the 
features and specification in the user manual 
does not match the actual functions, sorry for
any inconvenience and  thanks for your kind 
understanding!

When Installing the Unit

When Installing the Unit

2

Содержание FLP-PA4500D

Страница 1: ...ing overloading and short circuit Individual DC 24V inputs with wide voltage protection Product Features Model Rated Power Output Speaker Outputs Input Sensitivity Impedance Overload Electromotive For...

Страница 2: ...ctions in this manual to obtain the optimum resultsfrom this unit We also recommend that you keep this manual handyfor future reference OPERATION MANUAL TM TM PROFESSIONAL PUBLIC ADDRESS SYSTEM CLASS...

Страница 3: ...ENCLATURE AND FUNCTIONS 3 1 Front Panel 4 3 2 Rear Panel 4 4 OPERATING INSTRUCTION 5 5 WIRING INTRODUCTION 8 6 BLOCK DIAGRAM 10 8 OPERATING INSTRUCTIONS FAULT DETECTION 9 APPLICATIONS 11 9 11 10 SPECI...

Страница 4: ...r Make no further attempt to operate the unit in this condition as this may cause fire or electric shock If you detect smoke or a strange smell coming from the unit If water or any metallic object get...

Страница 5: ...ts on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that...

Страница 6: ...m supply for battery failure or damage of high voltage equipment 9 AC alternating current power supply pressure 10 Power amplifier output 100V voltage 11 Electrical equipment electrical isolation sign...

Страница 7: ...wer input 4 Stby indicator 5 24V DC indicator 6 Power indicator 7 POWER SWITCH Up turn on the power Down turn off the power 3 NOMENCLATURE AND FUNCTIONS 3 1 FRONT PANEL 3 2 REAR PANEL 4 3 11 16 8 2 1...

Страница 8: ...ltage range 100V speaker output 1 channels Class D amplifier output with source filters to pass invalid audio signal available for 100V external speaker The total power of the speakers connected to th...

Страница 9: ...or STBY THRU and GND are short cut the main power amplifier will be forced off The machine will turn to standby mode with consumption less than 60W They are electrically connected in parallel you can...

Страница 10: ...o have sufficient strength and current carrying capacity thereby ensuring under fault conditions exposed conductive parts will not lead to shock but not because of the current flowing through the poin...

Страница 11: ...nded to use symmetry balance shielded cable because the balance of signal noise and radio interference of AC power source is not so sensitive And unbalanced lines can cause noise especially when long...

Страница 12: ...LINE 10 LINE 9 LINE 8 LINE 7 L E F T RIG HT MIC INPUTS MIC LINE INPUTS P T T 1 2 3 4 5 6 7 8 9 10 CHIME REMOTE 2 OUTPUTS 1 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 POWER 24V 2A AUDIO OUT...

Страница 13: ...CH2 CH1 CH2 CH3 CH4 IR S2092S IR S2092S IR S 2092S IR S 2092S IR S2092S IR S2092S IR S2092S IR S2092S BP 00137 BP 00137 BP 00274 BP 00274 PA 01479 PWM PA 01479 PWM PA 01478 DC 18V BP 00137 BP 00137 B...

Страница 14: ...connect other equipments as well Pull up the power line after closing down In a sound system the amplifier should be the first to start up and the last to close down Starting up order First start up...

Страница 15: ...tivity Impedance 10 SPECIFICATIONS 12 100V LINE IN 775mV 10K 80Hz 16KHz 1dB 3dB 85dB 80Hz 16kHz 10dB below maximum power 0 2 1 kHz maximum power 1 85 After a forced air into the front 50 70 Thermostat...

Страница 16: ...11 DIMENSIONAL DIAGRAM UNIT mm 13 100 Over 100 Over Over 100 UNIT mm 3 64 64 10 465 444 5 66 74 5 437 484 44 4 13 7...

Страница 17: ...Version0 1 TM TM...

Отзывы: