background image

6

                                          

    O P E R A T I N G  I N S T R U C T I O N

In the following circumstances protect the LED is on

.In the self-test  procedure after the power is on, the LED is lit continuously on for about 2S. 

     In this process there is no output.

.the excessive signal causes clipping, the led flashes, the breif flashes makes no influence

     to the distortion. The excessive and continuous clipping may destroy the speakers. So pls 
     turn down the volume when the leds shin frequently.

.If the output cable is short cut, the indicator will keep on. But if the volume is turned off, the

     indicator may be off. Pls check the load and output cables.

.If the protect be shut down because of the over high temperature, pls turn the amp off, check 

     whether the ventilation or the wind grid is good.

.When the power is power during  working or the power supply voltage is too high, the indicator

     will keep on.

.If the amplifier fault is not in accordance to the above situations,  while the Protect indicator 

     keeps on, pls turn to the professional engineer.  

When the "STBY IN" and "GND" or "STBY THRU" and "GND" are short
cut, the main power amplifier will be forced off. The machine will turn to
standby mode, with consumption less than 60W.
They are electrically connected in parallel; you can input from one 
socket and output from another socket and connect to the remote 
standby control interface of the next amp.

Note: 

When  cascade, the GND terminal of the "Remote Standby control
interface" should connect to the GND terminal of the next one ac
-cordingly; otherwise it will cause the machine to turn to the standby 
mode and it cannot work properly.

STATE OUT

When the normal state circuit is operating, this port output high lever(+5 V).

The use of the terminal, according to the case-channel power ON / OFF 
state and the protection of the state, to control external connected device 
(monitor display panel) indicator lights up and the operation of the power 
of the lamp is turned on. 
The circuit is designed to monitor the voltage between terminals 5 and 6 
feet 5V; please currents when used in a closed environment below 12mA.

R

 1

5

V

 D
C

 R
E

L

A

Y

 

When the LED is lighted:

Control current
   under 12mA 

5 pinhole

6 pinhole

Monitor terminal

V

5

V

 E
X

T

E

R

N

A

L

 

P

O

W
E

R

 S
U

P

P

L

Y

 

REMOTE CONTROL INTERFACE AND REMOTE STANDBY INTERFACE

Содержание FLP-PA4500D

Страница 1: ...ing overloading and short circuit Individual DC 24V inputs with wide voltage protection Product Features Model Rated Power Output Speaker Outputs Input Sensitivity Impedance Overload Electromotive For...

Страница 2: ...ctions in this manual to obtain the optimum resultsfrom this unit We also recommend that you keep this manual handyfor future reference OPERATION MANUAL TM TM PROFESSIONAL PUBLIC ADDRESS SYSTEM CLASS...

Страница 3: ...ENCLATURE AND FUNCTIONS 3 1 Front Panel 4 3 2 Rear Panel 4 4 OPERATING INSTRUCTION 5 5 WIRING INTRODUCTION 8 6 BLOCK DIAGRAM 10 8 OPERATING INSTRUCTIONS FAULT DETECTION 9 APPLICATIONS 11 9 11 10 SPECI...

Страница 4: ...r Make no further attempt to operate the unit in this condition as this may cause fire or electric shock If you detect smoke or a strange smell coming from the unit If water or any metallic object get...

Страница 5: ...ts on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that...

Страница 6: ...m supply for battery failure or damage of high voltage equipment 9 AC alternating current power supply pressure 10 Power amplifier output 100V voltage 11 Electrical equipment electrical isolation sign...

Страница 7: ...wer input 4 Stby indicator 5 24V DC indicator 6 Power indicator 7 POWER SWITCH Up turn on the power Down turn off the power 3 NOMENCLATURE AND FUNCTIONS 3 1 FRONT PANEL 3 2 REAR PANEL 4 3 11 16 8 2 1...

Страница 8: ...ltage range 100V speaker output 1 channels Class D amplifier output with source filters to pass invalid audio signal available for 100V external speaker The total power of the speakers connected to th...

Страница 9: ...or STBY THRU and GND are short cut the main power amplifier will be forced off The machine will turn to standby mode with consumption less than 60W They are electrically connected in parallel you can...

Страница 10: ...o have sufficient strength and current carrying capacity thereby ensuring under fault conditions exposed conductive parts will not lead to shock but not because of the current flowing through the poin...

Страница 11: ...nded to use symmetry balance shielded cable because the balance of signal noise and radio interference of AC power source is not so sensitive And unbalanced lines can cause noise especially when long...

Страница 12: ...LINE 10 LINE 9 LINE 8 LINE 7 L E F T RIG HT MIC INPUTS MIC LINE INPUTS P T T 1 2 3 4 5 6 7 8 9 10 CHIME REMOTE 2 OUTPUTS 1 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 POWER 24V 2A AUDIO OUT...

Страница 13: ...CH2 CH1 CH2 CH3 CH4 IR S2092S IR S2092S IR S 2092S IR S 2092S IR S2092S IR S2092S IR S2092S IR S2092S BP 00137 BP 00137 BP 00274 BP 00274 PA 01479 PWM PA 01479 PWM PA 01478 DC 18V BP 00137 BP 00137 B...

Страница 14: ...connect other equipments as well Pull up the power line after closing down In a sound system the amplifier should be the first to start up and the last to close down Starting up order First start up...

Страница 15: ...tivity Impedance 10 SPECIFICATIONS 12 100V LINE IN 775mV 10K 80Hz 16KHz 1dB 3dB 85dB 80Hz 16kHz 10dB below maximum power 0 2 1 kHz maximum power 1 85 After a forced air into the front 50 70 Thermostat...

Страница 16: ...11 DIMENSIONAL DIAGRAM UNIT mm 13 100 Over 100 Over Over 100 UNIT mm 3 64 64 10 465 444 5 66 74 5 437 484 44 4 13 7...

Страница 17: ...Version0 1 TM TM...

Отзывы: