Servicing
8.3 Replacing wearing parts
M3600-02en
Edition 09/2022
47
4. Mount new buffers (5) on the bolts (4). Please observe the information in section Use
and storage of the buffers (5) (Page 74) when replacing the buffers (5).
5. Secure the buffers (5) with the washers (6) and the locking rings (12).
8.3.3.2
Replacing buffers (5) with removal of the bolts (4)
8.3 Replacing wearing parts
NOTICE
Blockage of cross bore of bolts (4)
The liquid screw locking agent can seal the cross bore of the bolts (4). Pressing out the
bolts (4) with grease then becomes difficult or completely impossible.
•
Apply only a small quantity of the liquid screw locking agent to the screws (11).
Procedure
1. Remove the bolts (4). Please observe the relevant information in section Pressing out
2. Remove the locking rings (12) and the washers (6).
3. Pull the buffers (5) off the bolts (4).
4. Clean the bolts (4), the washers (6), the locking rings (12), the buffer fitting holes and the
bolt fitting holes in the coupling parts 1 (1) and 2 (2) or 20 (20).
If old bolts (4) are to be reused, the tapped holes and cross bores must be completely
free of any residues of grease or liquid screw locking agent.
5. Mount new buffers (5) on the bolts (4). Please observe the information in section Use
and storage of the buffers (5) (Page 74) when replacing the buffers (5).
6. Secure the buffers (5) with the washers (6) and the locking rings (12).
7. Insert the bolts (4) with the buffers (5) into the bolt fitting holes. Observe any markings
that might be provided.
8. Push the washers (8) onto the screws (11).
9. Apply a small quantity of liquid screw locking agent (e.g. Loctite 243 medium strength) to
the screws (11).
10.Secure the bolts (4) with the screws (11) and washers (8).
11.Tighten the screws (11) to the specified tightening torque T
A
torques and widths A/F (Page 72)).
8.3.4
Pressing out bolts
8.3 Replacing wearing parts
The bolts (4) for coupling sizes 450 to 2 000 have cross bores that make it easier to press
out the bolts (4).
8.3.4.1
Pressing out bolts (4) with the "demounting box"
8.3 Replacing wearing parts
Flender can supply a "demounting box" which is a hydraulic press-out fixture for removing
bolts. Flender can supply the demounting box on request.
Содержание RUPEX
Страница 1: ...RWN RWS RFN RFS Assembly and operating instructions M3600 02en Edition 09 2022 RUPEX ...
Страница 6: ...Table of contents 6 Edition 09 2022 M3600 02en ...
Страница 8: ...List of tables 8 Edition 09 2022 M3600 02en ...
Страница 10: ...List of figures 10 Edition 09 2022 M3600 02en ...
Страница 14: ...Introduction 1 4 Copyright 14 Edition 09 2022 M3600 02en ...
Страница 36: ...Commissioning 36 Edition 09 2022 M3600 02en ...
Страница 42: ...Operation 7 2 Faults causes and rectification 42 Edition 09 2022 M3600 02en ...
Страница 54: ...Service and support 9 1 Contact 54 Edition 09 2022 M3600 02en ...
Страница 56: ...Disposal 56 Edition 09 2022 M3600 02en ...
Страница 62: ...Spare parts 11 2 Spare parts drawing and spare parts list 62 Edition 09 2022 M3600 02en ...
Страница 76: ...Technical data Buffers 5 76 Edition 09 2022 M3600 02en ...
Страница 78: ...Declaration of Conformity UK Declaration of Conformity 78 Edition 09 2022 M3600 02en ...
Страница 79: ......