2   ›P L AC I N G   A N D   FI L L I N G   T H E   TA N K

1)  Choose the final location for your water softener 

tank and place the tank upright and level on the 
surface. Filling the tank may be necessary on 
some systems. Your tank may have also come 
pre-filled, and in this case you only need to un-
screw the protective cap as shown in 

Figure 6-A

2) 

If your tank is not filled

, place the riser tube 

into the tank as shown in 

Figure 6-B

. Please 

make sure that the riser tube seats into the 
bottom of the tank and that the top of the tube is 
flush with the top of the tank opening 

F I G U R E   6 - A

F I G U R E   6 - B

›PR E - I N S TA L L AT I O N

Before assembly of your new system, be sure that the following conditions have been met for the place-
ment of your system:

•  Level, firm surface, such as concrete, on which 

to place the softener tank and salt tank (also 
known as a 

brine

 tank)

•  Un-switched power source, standard US plug, 

120v 60hz (the softener system includes a  
5 ft power cord and plug)

•  Access to the water main coming into your 

home. You will need to install the softener at 
this point to assure that water for the home is 
going through the system

•  Nearby floor drain or standpipe to connect to the 

softener for use during each regeneration

Well 

Pump or

City 

Meter

Water

Heater

Bypass

Bath

Sink

Toilet

Kitchen

Spigot

Spigot

Softener

Drain Line

Hard Water

Soft Water

Overflow

(Optional)

Floor

Drain

Содержание 5800 SXT

Страница 1: ...FLECK 5800 SXT METERED WATER SOFTENER INSTALL ATION GUIDE V1 0...

Страница 2: ...age 12 OU T L E T IN L E T DR AIN SE T TING INPU T VA LUE DF Display Format GAL Gallons VT Valve Type 5800 RF Regeneration Flow dF1b CT Control Type Fd Flow Delayed C UNIT CAPACITY 000 Grains H HARDNE...

Страница 3: ...ntrol Valve from QualityWaterForLess com We have put together these instructions as reference and to be used as general installation guidelines It is always recommended that a licensed plumber perform...

Страница 4: ...hardness level in PPM or mg L please divide this number by 17 1 to get Grains gpg Ex If your hardness is measured at 300 PPM take 300 17 1 18 gpg before iron 3 H COMPENSATED HARDNESS Your Iron result...

Страница 5: ...20K 10 Min 7 5 lbs Grid Grid NO GRID NO GRID 25 gpg 24K 14 Min 11 25 lbs Grid 3 Legs Grid Grid Grid 32K 1 0 cu ft 9x48 0 12 gpg 20K 8 Min 6 lbs Grid NO GRID NO GRID NO GRID TOO LARGE TOO LARGE 12 25 g...

Страница 6: ...IG U R E 6 A FIG U R E 6 B PRE INSTALL ATION Before assembly of your new system be sure that the following conditions have been met for the place ment of your system Level firm surface such as concret...

Страница 7: ...E 7 A FIG U R E 7 B 3 INSTALLING THE FLECK 5800 SX T VALVE 1 Remove the filling funnel and tape and while using the included silicone lubricant packet lu bricate the inner and outer o rings on the bot...

Страница 8: ...lines and use a wet rag on the lines being soldered to prevent heat damage during soldering 6 Once all connections have been made place the system into bypass by either using your existing 3 valve byp...

Страница 9: ...lso take this moment to prepare and insert the brine support grid determined from pages 4 and 5 Then pull the 474 Brine Float Assembly out of the brine well as shown in Figure 9 C 4 Next fix the 474 B...

Страница 10: ...e to recut the end of the tube each time you remove it to ensure a proper seal when the tube is inserted 8 Finally use inner diameter I D tubing to connect the drain barb fitting on the brine tank to...

Страница 11: ...ure 11 C Be sure that the fitting is fully inserted into the drain port by clicking it into place 4 Reinsert the drain fitting pin to lock the DLFC barbed drain fitting into the Fleck 5800 SXT con tro...

Страница 12: ...u may hold the button to allow the time to scroll faster Once the time display is set to 12 01 PM press the REGEN button once as shown in Figure 12 B 3 To enter MASTER PROGRAMMING MODE press the UP an...

Страница 13: ...your water listed on page 2 calculated on page 4 and press the REGEN button as shown in Figure 13 C 10 The display should now show RS SF as shown in Figure 13 D This indicates that the Reserve Select...

Страница 14: ...igure 14 A This indicates the system will regenerate at 2 00 AM following the day the water consumption has passed the calculated capacity If you prefer an alternate regeneration time please enter it...

Страница 15: ...wn in Figure 15 B This indicates Flow Relay Off Do not change this value and advance 21 The system will now exit Master Program ming mode and the display should now show the time of day followed by th...

Страница 16: ...of water needed to cover the brine grid into the brine tank Start the regeneration sequence by HOLDING the REGEN button for 5 seconds Once the screen stops flashing BW let BW Backwash run for about 1...

Отзывы: