7   ›PRO G R A M M I N G   T H E   F L EC K   5 8 0 0   SX T   VA LV E

1)  To begin programming, first plug in your 5800 

SXT Valve to a nearby wall outlet. The power port 
is located on the right side of the valve in front of 
the brine port (12-A). The system will illuminate 4 
digits. The system will show the time of day and 
the amount of gallons remaining before the next 
regneration. This display will switch between 
these values about every 10 seconds 

2)  Set the time on the system to 12:01 PM by 

pressing either the UP or DOWN button as 
shown in Figure. 

i

 

Be careful to confirm the 

presence of the PM symbol in the top right 

corner.

 You may hold the button to allow the 

time to scroll faster. Once the time display is set 
to 12:01 PM, press the REGEN button once as 
shown in Figure 12-B

3)  To enter MASTER PROGRAMMING MODE, 

press the UP and DOWN buttons TOGETHER 
and HOLD both for 5 seconds as shown in  
Figure 12-C 

4)  The display should now show 

DF / GAL

 as shown 

in Figure 12-D. This indicates U.S. Operational 
Mode measuring consumption in gallons. 

Do 

not change this value and press the REGEN 

button once to advance to the next setting

F I G U R E   12 - E

F I G U R E   12 - F

5)  The display should now show 

VT / 5800

 as 

shown in Figure 12-E. This indicates Valve Type 
5800 Mode. Do not change this value and press 
the REGEN button to advance to the next setting

6)  The display should now show 

RF / dF1b

 as 

shown in Figure 12-F. This indicates Regeneration 
Flow Downflow Single Backwash. Do not change 
this value and press the REGEN button to advance 
to the next setting

Содержание 5800 SXT

Страница 1: ...FLECK 5800 SXT METERED WATER SOFTENER INSTALL ATION GUIDE V1 0...

Страница 2: ...age 12 OU T L E T IN L E T DR AIN SE T TING INPU T VA LUE DF Display Format GAL Gallons VT Valve Type 5800 RF Regeneration Flow dF1b CT Control Type Fd Flow Delayed C UNIT CAPACITY 000 Grains H HARDNE...

Страница 3: ...ntrol Valve from QualityWaterForLess com We have put together these instructions as reference and to be used as general installation guidelines It is always recommended that a licensed plumber perform...

Страница 4: ...hardness level in PPM or mg L please divide this number by 17 1 to get Grains gpg Ex If your hardness is measured at 300 PPM take 300 17 1 18 gpg before iron 3 H COMPENSATED HARDNESS Your Iron result...

Страница 5: ...20K 10 Min 7 5 lbs Grid Grid NO GRID NO GRID 25 gpg 24K 14 Min 11 25 lbs Grid 3 Legs Grid Grid Grid 32K 1 0 cu ft 9x48 0 12 gpg 20K 8 Min 6 lbs Grid NO GRID NO GRID NO GRID TOO LARGE TOO LARGE 12 25 g...

Страница 6: ...IG U R E 6 A FIG U R E 6 B PRE INSTALL ATION Before assembly of your new system be sure that the following conditions have been met for the place ment of your system Level firm surface such as concret...

Страница 7: ...E 7 A FIG U R E 7 B 3 INSTALLING THE FLECK 5800 SX T VALVE 1 Remove the filling funnel and tape and while using the included silicone lubricant packet lu bricate the inner and outer o rings on the bot...

Страница 8: ...lines and use a wet rag on the lines being soldered to prevent heat damage during soldering 6 Once all connections have been made place the system into bypass by either using your existing 3 valve byp...

Страница 9: ...lso take this moment to prepare and insert the brine support grid determined from pages 4 and 5 Then pull the 474 Brine Float Assembly out of the brine well as shown in Figure 9 C 4 Next fix the 474 B...

Страница 10: ...e to recut the end of the tube each time you remove it to ensure a proper seal when the tube is inserted 8 Finally use inner diameter I D tubing to connect the drain barb fitting on the brine tank to...

Страница 11: ...ure 11 C Be sure that the fitting is fully inserted into the drain port by clicking it into place 4 Reinsert the drain fitting pin to lock the DLFC barbed drain fitting into the Fleck 5800 SXT con tro...

Страница 12: ...u may hold the button to allow the time to scroll faster Once the time display is set to 12 01 PM press the REGEN button once as shown in Figure 12 B 3 To enter MASTER PROGRAMMING MODE press the UP an...

Страница 13: ...your water listed on page 2 calculated on page 4 and press the REGEN button as shown in Figure 13 C 10 The display should now show RS SF as shown in Figure 13 D This indicates that the Reserve Select...

Страница 14: ...igure 14 A This indicates the system will regenerate at 2 00 AM following the day the water consumption has passed the calculated capacity If you prefer an alternate regeneration time please enter it...

Страница 15: ...wn in Figure 15 B This indicates Flow Relay Off Do not change this value and advance 21 The system will now exit Master Program ming mode and the display should now show the time of day followed by th...

Страница 16: ...of water needed to cover the brine grid into the brine tank Start the regeneration sequence by HOLDING the REGEN button for 5 seconds Once the screen stops flashing BW let BW Backwash run for about 1...

Отзывы: