7 ›PRO G R A M M I N G T H E F L EC K 5 8 0 0 SX T VA LV E
1) To begin programming, first plug in your 5800
SXT Valve to a nearby wall outlet. The power port
is located on the right side of the valve in front of
the brine port (12-A). The system will illuminate 4
digits. The system will show the time of day and
the amount of gallons remaining before the next
regneration. This display will switch between
these values about every 10 seconds
2) Set the time on the system to 12:01 PM by
pressing either the UP or DOWN button as
shown in Figure.
i
Be careful to confirm the
presence of the PM symbol in the top right
corner.
You may hold the button to allow the
time to scroll faster. Once the time display is set
to 12:01 PM, press the REGEN button once as
shown in Figure 12-B
3) To enter MASTER PROGRAMMING MODE,
press the UP and DOWN buttons TOGETHER
and HOLD both for 5 seconds as shown in
Figure 12-C
4) The display should now show
DF / GAL
as shown
in Figure 12-D. This indicates U.S. Operational
Mode measuring consumption in gallons.
Do
not change this value and press the REGEN
button once to advance to the next setting
F I G U R E 12 - E
F I G U R E 12 - F
5) The display should now show
VT / 5800
as
shown in Figure 12-E. This indicates Valve Type
5800 Mode. Do not change this value and press
the REGEN button to advance to the next setting
6) The display should now show
RF / dF1b
as
shown in Figure 12-F. This indicates Regeneration
Flow Downflow Single Backwash. Do not change
this value and press the REGEN button to advance
to the next setting