SECTION 1
INFORMATION AND REQUIREMENTS
1.0
APPLIANCE INFORMATION
Main injector : (1 off)
Stereomatic Injector Cat 82 – size 380 (NG)
Pilot Type :
ERTA PG-83-10
Max. Gross Heat Input :
5.4 kW
Min. Gross Heat Input :
3.0 kW
Gas Rate :
0.512 m3/hr (High)
0.290 m3/hr (Low)
Cold Pressure :
G20 20.0+/-1.0 mbar (8.0 +/- 0.4 in w.g.)
Ignition :
Integral to gas valve
Electrode Spark Gap :
4.0mm
Packed Weight
51.0 kg
Efficiency Declaration
The efficiency of this appliance has been measured as specified in
BS 7977-1 : 2009 + A1 2013 and the result is 73.9%.
The net calorific value of the fuel has been used for this efficiency
calculation. The test data from which it has been calculated has been certified by
BSI. The efficiency value may be used in the UK Government’s Standard
Assessment Procedure (SAP) for energy rating of dwellings.
Fig. 1
Fig. 2
Top View of Combustion
Side View of Combustion
Chamber
Chamber
3