background image

10

2.4

SECURING THE FIRE TO THE OPENING

2.4.1

The combustion chamber must be secured to the opening via the four 

off screw and rawlplugs provided.  Figure 8 & 9 below shows the hole 

centres in the mounting flanges of the combustion chamber.

Fig. 8

2.4.2

DO NOT SECURE THE COMBUSTION CHAMBER INTO THE 

OPENING AT THIS POINT AS ACCESS WILL STILL BE REQUIRED 

TO RUN THE GAS SUPPLY PIPEWORK AS DETAILED IN SECTION 

2.5

Fig. 9

371mm

779mm

4 holes in combustion

chamber mounting flange

for securing to the opening

Содержание Rocco HE FPHL RN2 Series

Страница 1: ...EFFICIENCY LOG EFFECT ROOM HEATER Installation Maintenance User Instructions Hand these instructions to the user Model No FPHL RN2 is for use on Natural Gas G20 at a supply pressure of 20 mbar in G B...

Страница 2: ...1 5kW Useful Efficiency at Nominal Heat Output 73 9 Useful Efficiency at Minimum Heat Output Indicative 50 0 Auxilliary Power Consumption at Nominal Heat Output 0 000001kW Auxilliary Power Consumptio...

Страница 3: ...ing the gas connection checking for gas tightness 18 3 3 Removal re fitting the trim 19 3 4 Fitting the batteries 20 21 3 5 Lighting the fire manually 21 3 6 Lighting the fire via the remote control h...

Страница 4: ...ode Spark Gap 4 0mm Packed Weight 51 0 kg Efficiency Declaration The efficiency of this appliance has been measured as specified in BS 7977 1 2009 A1 2013 and the result is 73 9 The net calorific valu...

Страница 5: ...58 Clay Flue Blocks and Terminals 7 IS 813 Domestic Gas Installation Republic of Ireland No purpose made additional ventilation is normally required for this appliance when installed in G B When Insta...

Страница 6: ...wall The appliance must however stand on a non combustible base that is a minimum thickness of 12mm 1 5 INSTALLATION TO PLASTERED WALL SURFACES If installing to a plastered wall all material must be...

Страница 7: ...guarantee card IMPORTANT NOTE BEFORE PROCEEDING WITH THE INSTALLATION This product requires a minimum effective flue height of 4 0 metres of minimum circular cross sectional area 125mm If installing...

Страница 8: ...n extra please order part number 1125 130260 from your local Flavel stockist 7 Minimum 50mm at sides Minimum 50mm at rear Combustion Chamber Dimension A Opening Width 750mm Dim A Dim B Dimension B Ope...

Страница 9: ...r servicing purposes If installing without a flue liner please ensure that sufficient depth is available in the opening to collect a minimum volumetric area of 12 litres 0 012m3 of flue debris This is...

Страница 10: ...area immediately above the fire is required see figure 7 above If there is no existing openings within either triangle proceed with forming the opening However if opening or beams occur within either...

Страница 11: ...ure 8 9 below shows the hole centres in the mounting flanges of the combustion chamber Fig 8 2 4 2 DO NOT SECURE THE COMBUSTION CHAMBER INTO THE OPENING AT THIS POINT AS ACCESS WILL STILL BE REQUIRED...

Страница 12: ...d Always insert the grommet into the entry point used a sharp blow with a hammer or chisel will be sufficient to knock out the opening selected in the firebox and with the grommet fitted cut with a sh...

Страница 13: ...itted into a Class 1 flue it may be desirable to fit the efficiency baffle 2 6 3 If the product is fitted into a Class 2 flue of diameter 125mm 5 then the restrictor baffle must not be fitted It shoul...

Страница 14: ...lamp brackets as shown below in figure 15 These are clamped together to form the seal between the glass frame assembly and the combustion chamber Fig 15 NOTE Always ensure that a consistent seal betwe...

Страница 15: ...rear section as shown to allow the fitting of Log A Fig 16 3 1 2 Place the largest Log A centrally onto the fuel bed support behind the burner flame strip Ensure that the fuel bed Log A is located ce...

Страница 16: ...base log A as shown below in figure 18 using the groove in Log A as a guide for placement Fig 18 3 1 4 Fit Log C into position on left hand side of the fuel bed base log A as shown below in figure 19...

Страница 17: ...e log A as shown below in figure 20 using the groove in Log A as a guide for placement Fig 20 3 1 6 Fit Log E into position at centre of the fuel bed base log A as shown below in figure 21 using the g...

Страница 18: ...wn below in figure 23 using the raised section in the base log as a guide for position Fig 23 IMPORTANT NOTE HAVING FITTED THE GRAVEL MATERIAL IN THE BASE OF THE COMBUSTION CHAMBER ENSURE THAT NONE OF...

Страница 19: ...duty polythene bag clearly labelled as RCF waste This is not classified as hazardous waste and may be disposed of at a tipping site licensed for the disposal of industrial waste Protective clothing is...

Страница 20: ...F THE TRIM ASSEMBLY 3 3 1 The trim is attached to firebox by 4 off magnets as shown below in figure 24 Fig 24 3 3 2 Ensure the trim is securely fitted to the fire 19 Fit trim to firebox and secure wit...

Страница 21: ...ator light is illuminated red after the batteries have been fitted as shown in figure 26 below Fig 26 20 IMPORTANT NOTE THE BATTERIES SHOULD BE REPLACED WITH GOOD QUALITY ALkALINE BATTERIES WHEN REQUI...

Страница 22: ...t input press and release the button to lower the heat input level one step at a time Pressing the button continuously will move the heat input level to the minimum 3 5 4 To increase the heat input le...

Страница 23: ...ght will the flash as the burner is being lit While the burner is lighting the red light will flash When the burner has lit the red light will stop completely The burner will now be lit at maximum hea...

Страница 24: ...remote handset as a backup the fire can be controlled from the valve which is located behind the trim on the fire see section 3 5 for full manual operating instructions If your fire does not operate m...

Страница 25: ...epeat the test after a further 5 10 minutes 3 7 4 If spillage persists the flue is not functioning correctly and a fault exists If after investigation the fault cannot be traced and rectified the fire...

Страница 26: ...After any servicing work a gas tightness check must always be carried out 4 1 Removing the burner assembly from the fire 4 1 1 Isolate the gas supply 4 1 2 Remove trim from the front of the fire as s...

Страница 27: ...ve the two fixing screws which secure the pilot assembly to the burner unit 4 3 6 Remove the pilot assembly 4 3 7 Re assemble with a new pilot assembly and carry out a gas tightness test after re asse...

Страница 28: ...least 300mm above the top of the appliance and the depth of the shelf does not exceed 150mm The fire may be installed below combustible shelves which exceed 150mm deep providing that the clearance abo...

Страница 29: ...son i e a GAS SAFE registered Engineer The service should include visually checking the appliance flue terminal and fireplace for accumulation of debris around the firebox and inspection of the cerami...

Страница 30: ...e immediately the power button The red light will the flash as the burner is being lit While the burner is lighting the red light will flash When the burner has lit the red light will stop completely...

Страница 31: ...andset as a backup the fire can be controlled from the valve which is located behind the ashpan cover on the fire see section 5 5 for full manual operating instructions If your fire does not operate m...

Страница 32: ...of the fire as shown below in figure 2 Fig 2 5 5 2 Ensure that the power isolation switch is in position 1 and the power indicator light is illuminated red as shown in figure 3 below Fig 3 32 Position...

Страница 33: ...e centre of the burner see section 5 5 slide the power isolator switch to the 0 position to the left 5 6 2 Remove the battery cover and replace the 3 off AA batteries with good quality Alkaline items...

Страница 34: ...without gloves could cause skin irritation The fuelbed should never be washed or exposed to any cleaning agents or water Any damaged parts must be replaced by contacting your dealer whose details may...

Страница 35: ...section as shown to allow the fitting of Log A 5 8 2 Place the largest Log A centrally onto the fuel bed support behind the burner flame strip Ensure that the fuel bed Log A is located centrally in th...

Страница 36: ...d base log A as shown below in figure 6 using the groove in Log A as a guide for placement Fig 6 5 8 4 Fit Log C into position on left hand side of the fuel bed base log A as shown below in figure 7 u...

Страница 37: ...ase log A as shown below in figure 8 using the groove in Log A as a guide for placement Fig 8 5 8 6 Fit Log E into position at centre of the fuel bed base log A as shown below in figure 9 using the gr...

Страница 38: ...osition at right hand side of the fuel bed base log A as shown below in figure 11 using the raised section in the base log as a guide for position Fig 11 Warning Use only the logs supplied with the fi...

Страница 39: ...rom these R C F articles is kept to a minimum during installation servicing we recommend that you use a HEPA filtered vacuum to remove any dust and soot accumulated in and around the fire before and a...

Страница 40: ...bottom of the combustion chamber by the two hinge clamp brackets as shown below in figure 13 These are clamped together to form the seal between the glass frame assembly and the combustion chamber Fi...

Страница 41: ...in figure 14 Fig 14 5 10 2 Ensure the trim is securely fitted to the fire IMPORTANT NOTE The trim assembly of this product is a working surface and as such will become hot in use Allow the product an...

Страница 42: ...of the user replaceable parts are as follows these are available from specialist spares stockists whose details can be found on our web site www bfm europe com in the stockist section Log Set B 109780...

Отзывы: