Before making the final gas connection, thoroughly purge the gas supply
pipe work to remove all foreign matter, otherwise serious damage may be
caused to the gas control valve on the fire.

2.4

GAS SOUNDNESS

a)

Remove the pressure test point screw from the inlet elbow and fit a 
manometer.

b)

Turn on the main gas supply and light the fire as described in section 
3.2 and carry out a gas soundness test.

c)

Check that the gas pressure is 20.0 mbar (± 1.0 mbar), 8.0 in w.g. +/- 
0.4 in w.g.

d)

Turn off the fire, remove the manometer and refit the pressure test point
screw. Check the pressure test point screw for gas soundness with the 
appliance turned on using a suitable leak detection fluid or detector.

3.1

Completing the Assembly

a)

Fit the radiants by carefully inserting the upper end first into the radiant 
canopy, and then lowering and seating the base of the radiants into the 
radiant support channel.

b)

Pull off the control knob.

c)

Fit the outer case by hooking rear edge of the case over the retaining 
lugs at each end of the rear panel.

d)

Ensure that the control bezel situated in the right hand side of the case 
clears the control valve spindle.

e)

Re-fit the outer case fixing screws situated at the front as shown in Fig. 
3 & 4 (page 9 &10 respectively)

f)

Refit the control Knob.

3.2

Lighting the Appliance

a)

Light the pilot by depressing the control knob at the “off” position and 
turn anti-clockwise (with the control depressed) to the second position 
marked *.

b)

When the pilot lights, (pilot can be seen through the bottom window of 
right hand radiant) hold the control knob down for 10 seconds.

c)

If the pilot fails to light, repeat the ignition sequence and hold in the 
control knob for slightly longer.

d)

When the pilot has lit, release the control knob from the depress
position, depress slightly again and turn the control anti-clockwise to the
large flame position and check for clearance of combustion products as 
detailed below.

13

Содержание FRCS3G

Страница 1: ...ing spares co Tel 0161 620 6677 STRATA Installation and Maintenance Instructions Hand these instructions to the user Model No s FRCS3G FRCS4G are only for use on Natural Gas G20 at a supply pressure o...

Страница 2: ...es 7 1 8 3 Fitting to Pre Cast Flue Installations 8 1 9 Hearth Fitting 8 1 10 Wall Mounting 8 1 11 Spillage Monitoring System 8 Section 2 2 1 Packing Check List 8 2 2 Installation of Fire 8 12 2 3 Gas...

Страница 3: ...s Heat Input 6 9 kW Min Gross Heat Input 2 5 kW Cold Pressure 20 0 1 0 mbar 8 0 0 4 in w g Ignition Rotary piezo integral to gas valve Electrode Spark Gap 4 0 mm Weight Packed 20 kg Firebox Dimensions...

Страница 4: ...Ventilation 3 B S 6891 Installation of Gas Pipework 4 B S 6461 Part 1 Installation of Chimneys Flues 5 B S 1251 Open Fireplace Components 6 B S 715 Metal Flue pipes for Gas Appliances 7 B S 1289 Clay...

Страница 5: ...f the fire and the shelf does not project more than 150 mm If the shelf overhangs more than 150 mm the distance between the fire and the shelf must be increased by 15 mm for every 25 mm of additional...

Страница 6: ...cture of the chim ney during or after the smoke pellet test and it is important to check inside upstairs rooms adjacent to the chimney flue Check the chimney pot terminal and gener al condition of the...

Страница 7: ...tchment Space 1 8 2 Fitting to Pre Fabricated twin wall metal Flue Boxes The appliance may be fitted to a twin wall metal flue box conforming to the constructional requirements of BS 715 for example t...

Страница 8: ...rds from the fire opening 1 10 WALL MOUNTING The fire can be fitted to non combustible walls The base of the fire must be at least 150mm above the floor level with the top of the fire place opening be...

Страница 9: ...way See Fig 2 Take care not to scratch the trim b Remove the radiants and their packaging from inside the fire and store in a safe place c Remove the two lower outer case fixing screws See Fig 3 and t...

Страница 10: ...Case Fixing Screws f Remove the flue spigot restrictor if the fire if the fire is the to be fitted to a pre cast flue The flue spigot restrictor is attached to the fire back with two screws g Fit the...

Страница 11: ...into the open ing the chimney may require attention DO NOT FIT THE FIRE SEEK EXPERT ADVICE Hearth Fitting a The feet must be fitted when hearth fitting Note When the fire is to be fitted onto a very...

Страница 12: ...s supplied d Offer the fire to the wall and push the spigot on the rear of the fire through the opening in the closure plate e Fit the 4 screws through the holes in the firebox back panel and tighten...

Страница 13: ...the base of the radiants into the radiant support channel b Pull off the control knob c Fit the outer case by hooking rear edge of the case over the retaining lugs at each end of the rear panel d Ens...

Страница 14: ...rance of combustion products Fig 6 e If the smoke is not drawn into the flue aperture remove the flue spigot restrictor if fitted and repeat the spillage test If there is an extractor fan fitted in a...

Страница 15: ...rate the fire and refer them to the User Book d Inform the User that the Model Number for ordering parts is shown on the Rating plate This is located on the inner face of the rear panel at the left ha...

Страница 16: ...ceramic should be checked and if necessary the whole set should be replaced with a genuine replacement set After any servicing work a gas soundness check must always be carried out 4 1 GENERAL ACCESS...

Страница 17: ...ket attached to the burner See section 4 3 c Unscrew injector fixing bracket See fig 8 d Unscrew four burner fixing screws See fig 9 e Carefully prise the injector to the right and out of the burner f...

Страница 18: ...alve lock nut from the top of the control valve d Unscrew the two control valve panel fixing screws fig 12 and remove valve and panel e Loosen and remove the three gas pipe retaining nuts from the con...

Страница 19: ...ther mocouple position is factory set to a tight tolerance Any replacement of parts on the pilot requires a complete new pilot assembly a Loosen the gas pipe nut and remove gas pipe from the pilot Th...

Страница 20: ...ts must be carried out by a competent person such as a CORGI registered gas installer The part numbers of the replaceable parts are as follows these are available from your local Flavel stockist whose...

Страница 21: ...620 6677 STRATA User Instructions These instructions should be read by the user before operating the appliance and retained for future reference Model No s FRCS3G FRCS4G are for use on Natural Gas G20...

Страница 22: ...ss of 150mm No purpose made additional ventilation is normally required for this appliance when installed in G B When installed I E please consult document I S 813 1996 Domestic Gas Installation which...

Страница 23: ...is or blockages which must be removed The chimney should also be checked to ensure clearance of flue products We recommend that during the annual service replacement of the Oxypilot is carried out Aft...

Страница 24: ...ress position depress slightly again and turn the control anti clockwise to the HIGH position and check for clearance of combustion products as detailed below WARNING If the fire goes out for any reas...

Страница 25: ...ics and brush gently with a soft brush To remove the ceramic remove the dress guard as shown in fig 2 Remove the radiants by lifting them slightly then pulling forward as shown below in Fig 3 Fig 3 RE...

Страница 26: ...s described in the above section Replacement of any other parts must be carried out by a competent person such as a CORGI registered gas installer The part numbers of the user replaceable parts are as...

Отзывы: