Supplied By www.heating spares.co Tel. 0161 620 6677
Closure plate.
a)
Fit the closure plate to the fireplace opening and ensure that it has a flat
sealing area of at least 10mm sealed on all sides. See Fig. 4 below
Dimensions stated are for closure plate supplied
Fig. 4
Check the operation of the chimney as follows:-
Apply a smoke match to the flue spigot opening in the closure plate and observe
the smoke. If there is a definite flow into the opening then proceed with the instal-
lation. If there is not a definite flow into the opening, pre-heat the chimney for
about two minutes and retest for flow. If there still is no definite flow into the open-
ing, the chimney may require attention. DO NOT FIT THE FIRE-SEEK EXPERT
ADVICE.
Hearth Fitting
a)
The feet
must be fitted
when hearth fitting.
Note
:
When the fire is to be fitted onto a very smooth surface eg marble or
tiles.
The 2 off self adhesive foam rubber discs, supplied should be stuck on
to the levelling screws at the front of the fire.
b)
Carefully place the fire on the hearth. Slide the fire backwards up to the
closure plate, ensuring that the flue spigot passes through the hole In
the closure plate.
c)
Level the fire by adjusting the levelling screws at the front of the feet.
d)
Proceed with the gas connection as in section 2.3
Minimum 10mm
Flat Sealing Area
Spigot Opening
660mm
460mm
493mm to
CTR
522mm Minimum
650mm Maximum
Fireplace
Opening
Dimensions
Closure
Plate
Dimensions
305mm Minimum
440mm Maximum
11