3.2 Configuration Jumpers
Configuration jumpers are located on the Controller Core PCB inside the beacon. A description
of each is provided below. To configure a particular option, move the spare jumper shunt to the
specified location.
Figure 3-2 – Configuration Jumpers
Table 3-2 – Configuration Jumpers
1. To activate mode override, the jumper must be installed while power is applied to the beacon.
The jumper has no effect if it is installed when the beacon is powered down.
2. Default flash rate is twenty (20) flashes per minute with no jumper installed on JP6 or JP7.
Jumper
Description
Function
JP1
1
MAN. NIGHT
Forces the beacon into Manual Night mode for 30 minutes.
JP2
1
MAN. DAY
Forces the beacon into Manual Day mode for 30 minutes.
JP3
-----
Spare Jumper
JP4
LEGACY
Unit operates at ½ duty cycle.
JP5
PD DEFEAT
The PD Alarm is disabled when the PD Defeat jumper is installed.
JP6
2
30 FPM
Thirty (30) flashes per minute.
JP7
2
40 FPM
Forty (40) flashes per minute.
JP8
SYNC1
(Lighting Equipment by others) Closed: Orga Sync (Open SYNC 2)
JP9
SYNC2
(Lighting Equipment by others) Closed: Unimar Sync (Open SYNC 1)
JP10
ALARM
(Jumper Installed) Reduces LED output below minimum regulatory
specification to test the system alarm circuitry.
Содержание VANGUARD FTS 370i-2
Страница 2: ...ii Revision A 05 17 2019 FTS 370i 2 IR This page intentionally left blank...
Страница 10: ...4 Revision A 05 17 2019 FTS 370i 2 IR Figure 1 2 Beacon Base Assembly Power Supply Surge Suppressors TB1...
Страница 19: ...FTS 370i 2 IR Revision A 05 17 2019 13 Figure 4 1 Beacon Wiring Diagram Standard...
Страница 20: ...14 Revision A 05 17 2019 FTS 370i 2 IR Figure 4 2 Beacon Wiring Diagram 10 Conductor Option...
Страница 26: ...20 Revision A 05 17 2019 FTS 370i 2 IR Figure 5 2 Base Component Locations...