FTB 312 and FTS 316
Revision13 — 02-20-2001
1-5
Table 1-3 PCB1 24740xx Jumper and Switch Settings
Jumper
or
Switch
†
Jumper
or Switch
Label
Description
JP1
INT RED
Uncut (all models).
JP2
RES PEC
Cut in all models to allow usage of a resistive photocell.
JP3
ALRMON2 Uncut.
JP4
NOBACK
Cut to disable white light backup for failure of the red flashhead. Installation dependent.
JP5
FAILCLOSE Uncut.
SW1-1
MRK0
Selects the marker lamp fail threshold. Chart etched on 24740 board shows “ALARM AT”
thresholds.
MARKER Parameter in Board Software = 4ORLESS
MARKER Parameter in Board Software = 5ORMORE
SW1-2
MRK1
Selects the marker lamp fail threshold. See the chart FOR SW1-1 above in this table.
JP8
CT
Cut to indicate top tier operation for this power converter in a catenary system. If both JP8 and
JP9 are cut or both uncut, operation is for the bottom tier.
JP9
CM
Cut to indicate middle tier operation for this power converter in a catenary system. If both JP8
and JP9 are cut or both uncut, operation is for the bottom tier.
JP10
ISOL
Cut to allow an alarm for only local alarm conditions on this power converter.
Uncut to allow an alarm for local alarms and alarms signalled though a communications
device.
JP11
RETROFIT
Cut to allow the 24740xx Circuit Board to emulate other boards on a tower of mixed circuit
boards.
JP12
MARKERNO
Uncut — energizes the marker relay in day mode and de-energizes it in night mode.
Cut —
de-energizes the marker relay in day mode and energizes it in night mode.
An energized marker relay turns off markers.
JP13
REDSENSE
Cut to enable the usage of sense boards. Uncut to allow usage with laminated transformers
(#8111). For internal design changes. Factory use only.
JP14
-
Uncut; factory use only.
JP15
-
Uncut; factory use only.
†
(Jumpers — OFF=CUT=OPEN)
Bulbs Installed
SW1-2/MRK1
SW1-1/MRK0
Alarm At
0
OFF
OFF
No alarms
2
OFF
ON
One bulb lit
3
ON
OFF
Two bulbs lit
4
ON
ON
Three bulbs lit
Bulbs Installed
SW1-2/MRK1
SW1-1/MRK0
Alarm At
0
OFF
OFF
No alarms
5
OFF
ON
Four bulbs lit
6
ON
OFF
Five bulbs lit
8
ON
ON
Six bulbs lit
Содержание FTB 312-3
Страница 8: ...viii Revision13 02 20 2001 FTB 312 and FTS 316 This page is intentionally blank ...
Страница 17: ...FTB 312 and FTS 316 Revision13 02 20 2001 1 9 474031 Figure 1 2 PCB1 Pictorial 24740xx ...
Страница 18: ...1 10 Revision13 02 20 2001 FTB 312 and FTS 316 474732 Figure 1 3 PCB1 Pictorial 24747xx ...
Страница 25: ...FTB 312 and FTS 316 Revision13 02 20 2001 2 7 FHMO Figure 2 2 Flashhead Mounting and Outline ...
Страница 26: ...2 8 Revision13 02 20 2001 FTB 312 and FTS 316 PEC510MO Figure 2 3 Photocell Mounting and Outline ...
Страница 27: ...FTB 312 and FTS 316 Revision13 02 20 2001 2 9 FIV1100MO Figure 2 4 Inverter Mounting and Outline ...
Страница 36: ...2 18 Revision13 02 20 2001 FTB 312 and FTS 316 FIV1100IW Figure 2 13 FIV 1100 Typical Installation Wiring ...
Страница 37: ...FTB 312 and FTS 316 Revision13 02 20 2001 2 19 FIV2000IW Figure 2 14 FIV 2000 Typical Installation Wiring ...
Страница 38: ...2 20 Revision13 02 20 2001 FTB 312 and FTS 316 ALRM2 Figure 2 15 Recommended Alarm Relay Wiring Protection ...
Страница 46: ...FTB 312 and FTS 316 Revision13 02 20 2001 2 28 This page is intentionally blank ...
Страница 62: ...3 16 Revision13 02 20 2001 FTB 312 and FTS 316 This page is intentionally blank ...
Страница 70: ...4 8 Revision13 02 20 2001 FTB 312 and FTS 316 PEC510CL Figure 4 7 PEC 510 Photocell ...
Страница 72: ...4 10 Revision13 02 20 2001 FTB 312 and FTS 316 This page is intentionally blank ...