FTB 312 and FTS 316
Revision13 — 02-20-2001
3-11
Setup to Check
Normal Default Night
Operation
Response — LEDs and Structure Lights
Perform the following proce-
dure for its power converter
in a multiple-unit system.
1) Cover the PEC with an
opaque (blocks all light)
cover.
2) Set the intensity select
switch or switches to
AUTO.
3) Remove power.
4) Disconnect the purple
wire on TB2-6. This fails
filter operation in the FH
306 Flashhead, and fails
the FH 307T Flashhead.
5) Reapply power.
Verify that the following responses occur as
compared to those in Check Normal Daytime
Operation, except for those in the following list
(after three flash cycles):
•
The WHT ALM LED
(I
8) is on.
•
The RED ALM LED
(I
13) is on.
•
The DAY LED
(I
5) is off.
•
The NITE LED
(I
10) is on for night opera-
tion.
•
The MKRS (markers) LED
(I
4) is off. It is off
during white night backup mode.
•
The system is flashing in white night
back-up intensity.
Remove power.
Reconnect the purple wire on TB2-6.
Restore all wires to their previous con-
nections before disconnecting any new
wires.
Reapply power.
Setup to Check
Marker Alarm Operation
Response — LEDs and Structure Lights
1) Cover the PEC with an
opaque (blocks all light)
cover.
2) Set the intensity select
switch or switches to
AUTO.
3) Remove power.
4) Remove fuse F4.
5) Reapply power.
Verify that the following responses occur as
compared to those in Check Normal Daytime
Operation, except for those in the following list
(after three flash cycles):
•
The DAY LED
(I
5) is off.
•
The NITE MODE LED
(I
10) is on.
•
The MKRS
(I
4) LED is on indicating that
markers should be on.
•
The MKR ALM
(I
7) LED is on indicating a
marker alarm.
•
The light is flashing in red mode (for the FH
306, the red filter is in place; or the FH 307T
Flashhead is flashing).
•
Remove power.
•
Replace F4 and recycle the unit
with the Intensity Select Switch as
done in Setup
•
Reapply power.
•
The unit should now be operating
normally in night mode; that is: red
light flashing, markers turned on,
and no alarm.
Remove the temporary opaque cover
placed over the PEC in Step 2.
Set Intensity Select Switch to AUTO.
Replace Fuse F4.
Setup to Check
White Alarm for Daytime
Operation
Response — LEDs and Structure Lights
1) Remove the opaque
cover from the PEC.
2) Set the intensity select
switch or switches to
AUTO.
3) Remove power.
4) Disconnect the black
wire from TB2-4.
5) Reapply power.
The following responses indicate a failure to
flash in day mode. Verify that they occur as
compared to those in Check Normal Daytime
Operation, except for those in the following list
(after three flash cycles):
•
The WHT ALM LED
(I
8) is on. (The power
converter executes 3 flash cycles internally
after power application. The White Alarm
turns on at the end of the three cycles.)
•
The DAY ERR LED
(I
7) is on.
•
The SYNC LED
(I
6) flicks on regu-
larly.
•
The CONF (flash confirm) LED
(I
11) is off.
Remove power.
Reconnect the black wire to TB2-4.
Reapply power.
Verify operation as in Daytime Opera-
tion.
Table 3-3 Checkout of Power Converters with PCB1 24747xx Board (Continued)
Содержание FTB 312-3
Страница 8: ...viii Revision13 02 20 2001 FTB 312 and FTS 316 This page is intentionally blank ...
Страница 17: ...FTB 312 and FTS 316 Revision13 02 20 2001 1 9 474031 Figure 1 2 PCB1 Pictorial 24740xx ...
Страница 18: ...1 10 Revision13 02 20 2001 FTB 312 and FTS 316 474732 Figure 1 3 PCB1 Pictorial 24747xx ...
Страница 25: ...FTB 312 and FTS 316 Revision13 02 20 2001 2 7 FHMO Figure 2 2 Flashhead Mounting and Outline ...
Страница 26: ...2 8 Revision13 02 20 2001 FTB 312 and FTS 316 PEC510MO Figure 2 3 Photocell Mounting and Outline ...
Страница 27: ...FTB 312 and FTS 316 Revision13 02 20 2001 2 9 FIV1100MO Figure 2 4 Inverter Mounting and Outline ...
Страница 36: ...2 18 Revision13 02 20 2001 FTB 312 and FTS 316 FIV1100IW Figure 2 13 FIV 1100 Typical Installation Wiring ...
Страница 37: ...FTB 312 and FTS 316 Revision13 02 20 2001 2 19 FIV2000IW Figure 2 14 FIV 2000 Typical Installation Wiring ...
Страница 38: ...2 20 Revision13 02 20 2001 FTB 312 and FTS 316 ALRM2 Figure 2 15 Recommended Alarm Relay Wiring Protection ...
Страница 46: ...FTB 312 and FTS 316 Revision13 02 20 2001 2 28 This page is intentionally blank ...
Страница 62: ...3 16 Revision13 02 20 2001 FTB 312 and FTS 316 This page is intentionally blank ...
Страница 70: ...4 8 Revision13 02 20 2001 FTB 312 and FTS 316 PEC510CL Figure 4 7 PEC 510 Photocell ...
Страница 72: ...4 10 Revision13 02 20 2001 FTB 312 and FTS 316 This page is intentionally blank ...