Setup to Check
Normal Nighttime
Operation
Response — LEDs and Structure Lights
Place opaque cover over pho-
tocell (block all light).
1) Intensity Select Switch in
AUTO.
2) Apply power (pull out inter-
lock switch plunger).
•
HV Warning Light is ON
•
NITE ERR LED
(I
1) is off.
•
DAY ERR LED
(I
7) is off.
•
PEC ALM
(I
2) is off.
•
WHT ALM LED
(I
8) is off.
•
RED ALM LED
(I
3) is off.
•
MKR ALM LED
(I
9) is off.
•
FAN LED
(I
4) not used.
•
SYNC LED
(I
10) flashes on in a regu-
lar pattern. May be difficult to see.
•
CONF LED
(I
5) “flashes” on after each
strobe flash. May be difficult to see.
•
DAY LED
(I
11) is off. Off at night.
•
NITE LED
(I
6) is on. On at night.
•
MKRS LED
(I
12) is on at night if mark-
ers are associated with the power con-
verter being observed.
•
NEON bulb
(I
13) is on; trigger voltage
is available; this bulb may flash.
•
Red strobe (either FH 306 or FH 307T)
is flashing at night intensity.
•
Associated red markers are on.
Setup to Check
Default Night Operation
Response — LEDs and Structure Lights
Perform this procedure for
each power converter individ-
ually in a multi-unit system.
1) Place opaque cover over
photocell (block all light).
2) Intensity Select Switch in
AUTO.
3) Remove power.
4) Disconnect purple wire on
TB2-6. This fails the red fil-
ter in the FH 306 and fails
the FH 307T Flashhead.
5) Reapply power.
Responses after three flash cycles:
•
HV Warning Light is ON
•
NITE ERR LED
(I
1) is off.
•
DAY ERR LED
(I
7) is off.
•
PEC ALM
(I
2) is off.
•
WHT ALM LED
(I
8) is on.
•
RED ALM LED
(I
3) is on.
•
MKR ALM LED
(I
9) is off. Goes on ini-
tially but then goes off when structure
enters white night back-up mode.
•
FAN LED
(I
4) not used.
•
SYNC LED
(I
10) flashes on in a regu-
lar pattern. May be difficult to see.
•
CONF LED
(I
5) “flashes” on after each
strobe flash. May be difficult to see.
•
DAY LED
(I
11) is off. Off at night.
•
NITE LED
(I
6) is on. On at night.
•
MKRS LED
(I
12) is off at night during
white back-up operation.
•
NEON bulb
(I
13) is on; trigger voltage
is available; this bulb may flash.
•
White strobe is flashing at white
back-up intensity.
•
Associated red markers are off.
Remove power.
Restore all wires to their previous posi-
tions before disconnecting any new wires.
Reconnect the purple wire on TB2-6.
Reapply power.
Setup to Check
Marker Alarm
Response — LEDs and Structure Lights
1) Place opaque cover over
photocell (block all light).
2) Intensity Select Switch in
AUTO.
3) Remove power.
4) Remove fuse F4.
5) Apply power.
Responses are the same as those for nor-
mal nighttime (previous) except for the fol-
lowing:
•
MKR ALM LED
(I
9) is on.
•
MKRS LED
(I
12) is on.
•
Red strobe (either FH 306 or FH 307T)
is flashing at night intensity.
•
Red markers are off.
Remove opaque cover over photocell.
Remove power.
Replace fuse F4.
Reapply power.
Setup to Check
White Alarm for Day Oper-
ation
Response — LEDs and Structure Lights
1) Remove opaque cover
over photocell.
2) Intensity Select Switch in
AUTO.
3) Remove power.
4) Disconnect black wire from
TB2-4.
5) Reapply power.
Responses are the same as those for day-
light (previous) except for the following:
•
DAY ERR LED
(I
7) is on.
•
WHT ALM LED
(I
8) is on. Turns on in
three flash cycles after applying power.
•
CONF LED
(I
5) is off.
•
White strobe is off.
Remove power.
Replace wire on TB2-4.
Reapply power.
Table 3-2 Checkout of Power Converters with PCB1 24740xx Board (Continued)
Содержание FTB 312-3
Страница 8: ...viii Revision13 02 20 2001 FTB 312 and FTS 316 This page is intentionally blank ...
Страница 17: ...FTB 312 and FTS 316 Revision13 02 20 2001 1 9 474031 Figure 1 2 PCB1 Pictorial 24740xx ...
Страница 18: ...1 10 Revision13 02 20 2001 FTB 312 and FTS 316 474732 Figure 1 3 PCB1 Pictorial 24747xx ...
Страница 25: ...FTB 312 and FTS 316 Revision13 02 20 2001 2 7 FHMO Figure 2 2 Flashhead Mounting and Outline ...
Страница 26: ...2 8 Revision13 02 20 2001 FTB 312 and FTS 316 PEC510MO Figure 2 3 Photocell Mounting and Outline ...
Страница 27: ...FTB 312 and FTS 316 Revision13 02 20 2001 2 9 FIV1100MO Figure 2 4 Inverter Mounting and Outline ...
Страница 36: ...2 18 Revision13 02 20 2001 FTB 312 and FTS 316 FIV1100IW Figure 2 13 FIV 1100 Typical Installation Wiring ...
Страница 37: ...FTB 312 and FTS 316 Revision13 02 20 2001 2 19 FIV2000IW Figure 2 14 FIV 2000 Typical Installation Wiring ...
Страница 38: ...2 20 Revision13 02 20 2001 FTB 312 and FTS 316 ALRM2 Figure 2 15 Recommended Alarm Relay Wiring Protection ...
Страница 46: ...FTB 312 and FTS 316 Revision13 02 20 2001 2 28 This page is intentionally blank ...
Страница 62: ...3 16 Revision13 02 20 2001 FTB 312 and FTS 316 This page is intentionally blank ...
Страница 70: ...4 8 Revision13 02 20 2001 FTB 312 and FTS 316 PEC510CL Figure 4 7 PEC 510 Photocell ...
Страница 72: ...4 10 Revision13 02 20 2001 FTB 312 and FTS 316 This page is intentionally blank ...