- 16 -
GAS TRAIN LEGEND
GAS SUPPLY & FLOW DIRECTION
OF GAS
GAS APPLIANCE PRESSURE
REGULATOR
AS SUPPLY MAIN SHUTOFF MANUAL
VALVE (FIELD SUPPLIED
SAFETY SHUTOFF GAS VALVE
(VS) 24V OR 120V SUPPLIED)
OPERATED
GAS SUPPLY PRESSURE TEST
POINT (FIELD SUPPLIED)
MAIN GAS VALVE (V1) 24V OR 120V
OPERATED SINGLE STAGE
GAS TRAIN PIPE DIAMETER SIZE(S):
BURNER G120 1/2" NPT (REDUCED
AT COMBUSTION HEAD TO 3/8")
BURNER(S) G200 & G400 3/4" NPT
GAS BURNER MANIFOLD TEST POINT
GAS SUPPLY PRESSURE RANGES:
NATURAL GAS PRESSURE:
MIN. = 4.0
″
WC
MAX. 10.0
″
WC
L.P. PROPANE GAS PRESSURE
MIN. = 8.0
″
WC
MAX. 13.0
″
WC
FIELD WIRING DIAGRAM
Содержание FVN-400