- 3 -
construction heater under Standard ANSI Z83.7/
CGA 2.14. 2000.
We cannot anticipate every use which may be made
of our heaters. CHECK WITH YOU LOCAL FIRE
SAFETY AUTHORITY IF YOU HAVE QUESTIONS
ABOUT APPLICATIONS.
Other standards govern the use of fuel gases and heat
producing products in specific applications. Your local
authority can advise you about these.
SPECIFICATIONS
Model …………………………………………………….….
FVNP-400
Input …………………………………………………….…...
390,000 btuh
Fuel ………………………………………………………….
Propane /
Natural Gas
Manifold Pressure ………………………………………….
1.5” W.C. Propane
2.0” W.C. NG
Maximum Inlet Pressure …………………………………
13.0” W.C. Propane
10.0” W.C. NG
Ignition ………………………………………………………
Direct Spark Ignition
…….……………………………………………...…
Thermostat Control
Air Circulation ……………………………………………….
2500 cfm
Fuel Consumption ……………………………………….....
18.5 lbs/hr Propane
380 cfh NG
Approved ………………………………………………….....
cETLus listed
INSTALLATION:
Содержание FVN-400
Страница 20: ...EXPLODED FVNP 400 SPARE PARTS LIST ...