by the doctor into the lower part (C1.1). Close the nebuliser by turning the upper part
(C1.3) clockwise.
3. Connect accessories as indicated in the “Connection diagram” on the cover.
4. Sit comfortably holding the nebuliser in your hand, place the mouthpiece onto your
mouth or alternatively use the nose piece or mask. Should
you opt for the mask accessory, place it on your face as
shown in the picture (with or without using the elasticated
strap).
5. Turn on the device using the switch (A1) and then breathe
in and exhale deeply.
6. When the treatment is finished, shut off the device and
unplug the power cord.
WARNING: If after the therapy session moisture accumulates
in the tube (B), remove the tube from the nebulizer and dry it using the device’s
compressor fan; this operation will prevent mold from forming inside the tube.
USE METHODS OF THE RF7 DUAL SPEED PLUS NEBULISER WITH SPEED SELECTION
AND VALVULAR SYSTEM
It is professional, quick, recommended to administer all types of medications, including
the costlier ones, even in patients with chronic diseases. Thanks to the
geometry of the RF7 Dual Speed Plus nebuliser cup internal ducts, we
have obtained a recommended, active particle size to treat even the
lower respiratory tract.
For faster inhalation therapy, position the valve speed selector (C1.4)
pressing on the word MAX with your finger.
For more effective inhalation therapy, position the valve speed selector
(C1.4) pressing on the opposite side of the word Max with your finger.
In this case, you have optimal assumption of the medication, minimising
leaks into the surrounding environment, thanks to the valvular system
with which the nebuliser cup, mouthpiece and mask are equipped.
MAX
SOFTTOUCH FACE MASKS
During inspiration the vent
bends inwards.
During expiration the vent bends
outwards.
The new SoftTouch Masks feature an adaptive edge made
of a soft biocompatible material ensuring an excellent
adherence to the face and a Dispersion Limiting Vent.
These innovations, which make them stand out from the
rest, allow increased sedimentation of medication in the
lungs and reduced dispersion into the air.
Soft
biocompatible
material
Dispersion
Limiting Vent
Содержание NebulFlaem PRO
Страница 2: ......
Страница 58: ...56 1 7 FLAEM FLAEM F400 400 F700 700 F1000 1000 F2000 2000 a b 93 42 CE...
Страница 62: ...60 RF7 dual speed plus ACO464P 2 ACO225P ACO462P 2 ACO164P 134 C 10 ISO17665 1 A3 Flaem...
Страница 63: ...61 FLAEM...
Страница 66: ...64 A7 1 C1 3 C1 2 2 C1 3 C1 4 C1 F1000 1000 F700 700 F400 400 F2000 2000 93 42 CE...
Страница 69: ...67 C1 1 C1 C1 3 3 4 A1 5 6 B RF7 DUAL SPEED PLUS RF7 Dual Speed Plus C1 4 MAX C1 4 MAX MAX SOFTTOUCH SoftTouch...
Страница 70: ...RF7 Dual Speed Plus ACO464P ACO225P 2 ACO462P ACO164P A3...
Страница 72: ...70 T V CE CEE 93 42 BF EN10993 1 EEC 93 42 1907 2006 CE IP21 IP21 12 EN 60 60601 1 2 2015 www flaemnuova it...
Страница 73: ...71...
Страница 75: ...73...