Five Seasons FS-GM20AS-A Скачать руководство пользователя страница 2

1 Dirty Air 

 

 

 

2 Prefilter 

 

 

3 Ionizing

 

   Section 

 

 

CONTENTS 

SAFETY CONSIDERATIONS                                           2 
WHAT THE ELECTRONIC AIR CLEANER DOES           2 
BENEFITS                                                                        2 
DESCRIPTION                                                                 2 
HOW IT WORKS                                                              2 
MAJOR COMPONENTS                                                   3 
INSTALLATION                                                                3 
Location                                                                            3 
Installation                                                                         3 
Wiring                                                                                3 
SYSTEM CHECK                                                              3 
OPERATION                                                                     3 
WHITE DUST                                                                    4 
MAINTENANCE                                                                4 
Cell and Prefilter Cleaning                                                4 
SERVICE                                                                       4-9 
Testing Air Proving Switch (APS)                                     4 
Replacing An Air Proving Switch (APS)                           4 
Testing For High Voltage At Power Board                        5 
Replacing Performance Light                                            5 
Replacing A Power Board                                                 5 
Testing The 24 V Transformer                                          5 
Replacing The 24 V Transformer                                      5 
Testing Voltage Of Power Board                                      6 
Testing Voltage At Cell                                                     6 
Setting Approximate Voltage With High Voltage Meter    6 
Testing Cell For Bad Contacts                                          6 
Replacing A Tungsten Ionizing Wire                                 6 
TROUBLESHOOTING GUIDE                                         9 
WARRANTY                                                                   10 

SAFETY CONSIDERATIONS 

Read and follow instructions carefully. Follow all local 

electrical  codes  during  installation.  All  wiring  must 
conform  to  local  and  national  electrical  codes.  Improper 
wiring or installation may damage Air Cleaner. 

Understand  the  signal  words  WARNING  and 

CAUTION which are present in the Owner’s Manual. 

WARNING  and  CAUTION  signifies  a  hazard  which 

could result in property damage, personal injury or death. 

 

 
Installation  and  servicing  of  Electronic  Air 

Cleaners  can  be  hazardous.  Only  trained  and 
qualified  service  personnel  should  install,  repair,  or 
service Electronic Air Cleaners. 

Homeowners or untrained personnel can perform 

the  basic  maintenance  functions  of  cleaning  and 
replacing filters. 

When working on air cleaning equipment, observe 

precautions in the manual, labels attached to the unit, 
and  other  safety  precautions  that  may  apply.  Follow 
all  safety  codes.  Wear  safety  glasses  and  work 
gloves. 

WHAT THE ELECTRONIC AIR CLEANER DOES 

Your High Efficiency Electronic Air Cleaner has been 

designed  to  remove  atmospheric  and  household  dust, 
coal  dust,  insecticide  dust,  mites,  pollen,  mold  spores, 
fungi,  bacteria,  pet  dander,  cooking  smoke  and  grease, 
tobacco  smoke  particles,  and  more  down  to  0.01  micron 
(0.01 micron = 1/2,540,000 of an inch). 

BENEFITS 

Helps provide relief for allergy or asthma suffering. 
Helps  prevent  damaging  black  dust  from  staining 
walls  and  furnishings,  reducing  the  amount  of  time 
and money spent cleaning and redecorating. 
Helps  protect  heating/cooling  equipment,  prolonging 
the operating efficiency. 
Improves  indoor  air  quality  for  a  healthier 
environment, year-round. 

DESCRIPTION 

The  Electronic  Air  Cleaner  is  approximately  29  x  25  x  7 
inches (73.6 x 63.5 x 17.8 cm).  The unit is designed to be 
wall  or  ceiling  mounted  in  the  main  return  air  duct  of  a 
forced  air  system.    The  intake  grille  is  hinged  to  allow 
easy access to the collecting cells and prefilters.  The unit 
is rated up to 2000 CFM (3398 m

3

/hr). 

HOW IT WORKS 

The  High  Efficiency  Electronic  Air  Cleaner  operates 

on  the  principle  of  electrostatic  precipitation.  Millions  of 
airborne pollutants are carried through the return air duct 
of  the  heating/cooling  system  and  treated  through  three 
stages of filtration. 

The 

prefilters  (2)

  remove  all  large  visible  particles 

such  as  lint.    Smaller  particles  then  pass  through  a 

two-

stage  electrostatic  collecting  cell  (2).

  First,  particles  are 

given a powerful positive electrical charge by the ionizing 
wires. Second, charged particles move into the collecting 
area  where  they  are  attracted  to  a  series  of  grounded 
plates.  Pollutants  are  held  in  this  section  like  a  magnet 
until washed away during cleaning. 

 

 

 
 
 
 
 
 

 
 

 
 
 
 

IMPORTANT:

  Please read entire instructions before 

installing the Electronic Air Cleaner. 

WARNING 

 

Before  beginning  any  installation  or  modification,  be 
certain that the main line electrical disconnect switch is 
in 

OFF

  position.  Electric  shock  could  result.  Tag 

disconnect switch with suitable warning labels. 

 

1 Dirty Air 

 

 

 

 

2 Prefilter 

 

 

3 Ionizing

 

          Section

 

 
4 Collecting Cell Plates 
 

 
 

5 Clean Air to Heating/Cooling 
   System 

Fig. 1 

Содержание FS-GM20AS-A

Страница 1: ...cting Cells are durable and easy to maintain Plastic Intake Grille is easy to wipe clean Hinged Swing Out Door allows easy access to filters Automatic interlock switch disconnects power when unit is opened Durable Scratch Resistant powder coat paint finish resists abrasion Electronic Air Proving Switch allows for quick wiring and cycles air cleaner on off with system fan Indicator Light shows Air ...

Страница 2: ...mospheric and household dust coal dust insecticide dust mites pollen mold spores fungi bacteria pet dander cooking smoke and grease tobacco smoke particles and more down to 0 01 micron 0 01 micron 1 2 540 000 of an inch BENEFITS Helps provide relief for allergy or asthma suffering Helps prevent damaging black dust from staining walls and furnishings reducing the amount of time and money spent clea...

Страница 3: ... the enclosure Remove the five screws securing the electrical compartment cover The hole in wall or ceiling should be made to fit the Air Cleaner opening as closely as possible The opening should be framed to provide adequate support for the Air Cleaner Before mounting the Air Cleaner cover the framing and close the opening to within 1 4 in 63 cm of the dimension of the rear of the enclosure of th...

Страница 4: ...etergent is available from your installer or dealer SERVICE Testing Air Proving Switch APS The APS sensor must protrude into the airstream to work effectively The sensor is very sensitive and operation may be affected by cold temperatures an air exchanger or a fresh air duct connected to the cold air return near the Air Cleaner The APS uses a Triac in its output circuit which affects the voltage s...

Страница 5: ...urn off power to the Air Cleaner at the source 1 Remove the electrical compartment cover 2 Disconnect wiring from the LED HV1 HV2 and 24 V terminals 3 Remove the hex nut from the power board 4 Release the power board from the 3 plastic board spacers by pinching the end of the spacers and pulling the board out 5 Push new board onto spacers Make sure spacers click into place to hold down board 6 Scr...

Страница 6: ...age should be reset with a high voltage meter as soon as possible 1 Remove electrical compartment cover 2 Turn the HV ADJ potentiometer fully counterclockwise Air Cleaner may arc or snap at this point 3 Turn the HV ADJ potentiometer clockwise slowly until the arcing and snapping stops 4 Replace electrical compartment cover Testing Cell For Bad Contact 1 Turn off power switch Open access door to Ai...

Страница 7: ...nizing Wire Table 2 Specifications Ionizing Bar Spring Wire Fig 4 Schematic MODEL FS GM20AS A HOUSE SIZE n a AIR FLOW up to 2000 cfm DUCT SIZE 22 x 29 1 in CABINET DIMENSIONS 31 4 x 24 4 x 7 WEIGHT 38 lbs POWER 120 v 60 hz ...

Страница 8: ...Fig 6 Exploded View Fig 5 Dimensions ...

Страница 9: ...ry Ducts were not cleaned prior to installation of air cleaner Clean ducts Cell plate s are bent Remove cells and adjust to original spacing using needle nose pliers Voltage is too high Adjust high voltage potentiometer on power board clockwise Contacts on high voltage tray are broken or bent If possible pull up contacts with needle nose pliers or remove high voltage tray and replace contacts Arro...

Страница 10: ...arts or replacement parts Such costs may be covered by a separate warranty provided by the dealer LIMITATIONS OF WARRANTY All implied warranties including implied warranties of merchantability are hereby limited in duration to the period for which the limited warranty is given The expressed warranties made in this warranty are exclusive and may not be altered enlarged or changed by any distributor...

Отзывы: