LIMITED FIVE (5) YEAR WARRANTY

 

 

FIVE  YEAR  WARRANTY  - 

This  FIVE  SEASONS  product  is  warranted  to  be  free  from  electrical  and  mechanical 

defects in material and  workmanship, under normal use and maintenance  within its listed capacity, for a period of 
FIVE (5) years from the date of original installation.  The FIVE SEASONS product must not have been moved from 
the site of original installation.  A new or remanufactured part to replace the defective part will be provided without 
charge  for  the  part  itself,  through  an  authorized  FIVE  SEASONS  service  dealer,  provided  the  defective  part  is 
returned  to  the  FIVE  SEASONS  distributor 

prepaid

.    The  replacement  part  assumes  the  unused  portion  of  the 

warranty.  

Proof  of  Purchase  and  Installation

 must be provided.  Failing this, FIVE SEASONS will guarantee the 

unit for a period of sixty (60) months from the date of manufacture, according to the manufacturer’s records.  The 
warranty does not include the prefilters. 
 

THIS WARRANTY DOES NOT INCLUDE ANY ADDITIONAL LABOR ALLOWANCE OR OTHER COSTS

 incurred 

for diagnosis, repairing, removing, installing, shipping, servicing, or handling of either defective parts or replacement 
parts.  Such costs may be covered by a separate warranty provided by the dealer. 
 

LIMITATIONS  OF  WARRANTY 

- All implied warranties (including implied warranties of merchantability) are hereby 

limited  in  duration  to  the  period  for  which  the  limited  warranty  is  given.    The  expressed  warranties  made  in  this 
warranty  are  exclusive  and  may  not  be  altered,  enlarged,  or  changed  by  any  distributor,  dealer  or  other  person 
whatsoever. 
 

FIVE SEASONS COMFORT LIMITED WILL NOT BE RESPONSIBLE FOR: 

1.  Normal  maintenance  as  outlined  in  the  Owner’s  Manual  including  cleaning  of  electronic  collecting  cells  or 

prefilters. 

2.  Damage or repairs required as a consequence of faulty installation or application by others. 
3.  Damage  or  repairs  needed  as  a  consequence  of  any  misapplication,  negligent  handling,  improper  servicing, 

unauthorized alteration, or improper operations. 

4.  Failure  to  start  due  to  voltage  conditions,  blown  fuses,  open  circuit  breakers  or  other  damages  due  to  the 

inadequacy or interruption of electrical service. 

5.  Damage as a result of floods, winds, fires, lightning, accidents, corrosive atmosphere, or other conditions beyond 

the control of FIVE SEASONS COMFORT LIMITED. 

6.  Parts not supplied or designated by FIVE SEASONS COMFORT LIMITED. 
7.  FIVE  SEASONS  COMFORT  LIMITED  products  installed  outside  the  continental  U.S.A.,  Alaska,  Hawaii,  and 

Canada. 

8.  Any personal injury, special indirect or consequential property or commercial damage of any nature whatsoever. 
 

Model No. 

 

 

 

 

 

Serial No. 

 
Date Of Installation 

 

 

 

 

Installed By 

 
Owner’s Name & Address 

 

RETAIN THIS CERTIFICATE WITH YOUR VALUABLE DOCUMENTS 

Содержание FS-GM20AS-A

Страница 1: ...cting Cells are durable and easy to maintain Plastic Intake Grille is easy to wipe clean Hinged Swing Out Door allows easy access to filters Automatic interlock switch disconnects power when unit is opened Durable Scratch Resistant powder coat paint finish resists abrasion Electronic Air Proving Switch allows for quick wiring and cycles air cleaner on off with system fan Indicator Light shows Air ...

Страница 2: ...mospheric and household dust coal dust insecticide dust mites pollen mold spores fungi bacteria pet dander cooking smoke and grease tobacco smoke particles and more down to 0 01 micron 0 01 micron 1 2 540 000 of an inch BENEFITS Helps provide relief for allergy or asthma suffering Helps prevent damaging black dust from staining walls and furnishings reducing the amount of time and money spent clea...

Страница 3: ... the enclosure Remove the five screws securing the electrical compartment cover The hole in wall or ceiling should be made to fit the Air Cleaner opening as closely as possible The opening should be framed to provide adequate support for the Air Cleaner Before mounting the Air Cleaner cover the framing and close the opening to within 1 4 in 63 cm of the dimension of the rear of the enclosure of th...

Страница 4: ...etergent is available from your installer or dealer SERVICE Testing Air Proving Switch APS The APS sensor must protrude into the airstream to work effectively The sensor is very sensitive and operation may be affected by cold temperatures an air exchanger or a fresh air duct connected to the cold air return near the Air Cleaner The APS uses a Triac in its output circuit which affects the voltage s...

Страница 5: ...urn off power to the Air Cleaner at the source 1 Remove the electrical compartment cover 2 Disconnect wiring from the LED HV1 HV2 and 24 V terminals 3 Remove the hex nut from the power board 4 Release the power board from the 3 plastic board spacers by pinching the end of the spacers and pulling the board out 5 Push new board onto spacers Make sure spacers click into place to hold down board 6 Scr...

Страница 6: ...age should be reset with a high voltage meter as soon as possible 1 Remove electrical compartment cover 2 Turn the HV ADJ potentiometer fully counterclockwise Air Cleaner may arc or snap at this point 3 Turn the HV ADJ potentiometer clockwise slowly until the arcing and snapping stops 4 Replace electrical compartment cover Testing Cell For Bad Contact 1 Turn off power switch Open access door to Ai...

Страница 7: ...nizing Wire Table 2 Specifications Ionizing Bar Spring Wire Fig 4 Schematic MODEL FS GM20AS A HOUSE SIZE n a AIR FLOW up to 2000 cfm DUCT SIZE 22 x 29 1 in CABINET DIMENSIONS 31 4 x 24 4 x 7 WEIGHT 38 lbs POWER 120 v 60 hz ...

Страница 8: ...Fig 6 Exploded View Fig 5 Dimensions ...

Страница 9: ...ry Ducts were not cleaned prior to installation of air cleaner Clean ducts Cell plate s are bent Remove cells and adjust to original spacing using needle nose pliers Voltage is too high Adjust high voltage potentiometer on power board clockwise Contacts on high voltage tray are broken or bent If possible pull up contacts with needle nose pliers or remove high voltage tray and replace contacts Arro...

Страница 10: ...arts or replacement parts Such costs may be covered by a separate warranty provided by the dealer LIMITATIONS OF WARRANTY All implied warranties including implied warranties of merchantability are hereby limited in duration to the period for which the limited warranty is given The expressed warranties made in this warranty are exclusive and may not be altered enlarged or changed by any distributor...