P/N 562179
REV. C Dec 2011
8
© 2011 Fisnar
Cycle Mode
Cycle Mode allows the user to create a repeating cycle of dispensing. This is programed by setting a wait time between
dispensing. This mode is reliant on the previous setting that was made in Timer Mode to determine the length of
dispensing during the cycle.
For Example:
If you would like to dispense for 1 second then wait for 5 seconds and cycle these times over again you
would need to have already set your Timer Mode for 1 second (see previous page for these instructions). To set the 5
second wait time in your cycle follow the below directions.
1. Press the
Mode
button until the Cycle Mode is selected.
2. Press the
Set
button. The first digit on the right side of the display will start blinking.
3. Press the
◄ button
two times. The third digit from the right should be blinking.
4. Press the
▲ button f
ive times. The display should now show a 5 second wait time. (To adjust the decimal refer to
page 11)
5. Press
Exit/Mode
to save as current setting.
To use the cycle mode press the
SHOT
button on the SL101N to activate the cycle. To deactivate the cycle press the
EXIT
button.