P/N 562179
REV. C Dec 2011
10
© 2011 Fisnar
Loading from Memory
After saving your Cycle Mode and Timer Mode settings to the SL101N memory you can then recall them to be used
again. Both the Cycle Mode and Timer Mode need to be loaded separately by switching to the mode you would like to
load.
For Example:
To load the cycle time that was saved in memory 9 on the previous page follow the below steps.
1. Switch to Cycle Mode then press and hold the
MEM
(Memory)
key for 2 seconds until the unit beeps.
2. The display will show
Ld 1
(Load from Memory #1).
3. Press the
▲
key 8 times to get to memory address 9.
4. Press the
EXIT
key to complete the load. Program 9 Cycle Mode settings are now in effect. The display should
show 5 seconds.
To load the timer mode settings switch to Timer Mode then follow the same directions.