Fisher EMERSON ACE95JR Скачать руководство пользователя страница 12

Type ACE95JR

©Emerson Process Management Regulator Technologies, Inc., 2001, 2016; All Rights Reserved

The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls International LLC, 

a business of Emerson Process Management.

The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or 

guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such 

products at any time without notice.

Emerson Process Management Regulator Technologies, Inc. does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and 

maintenance of any Emerson Process Management Regulator Technologies, Inc. product remains solely with the purchaser.

Industrial Regulators

Emerson Process Management 

Regulator Technologies, Inc.

USA - Headquarters

McKinney, Texas 75070 USA

Tel: +1 800 558 5853

Outside U.S. +1 972 548 3574

Asia-Pacific

Shanghai 201206, China

Tel: +86 21 2892 9000 
Europe

Bologna 40013, Italy

Tel: +39 051 419 0611
Middle East and Africa

Dubai, United Arab Emirates

Tel: +971 4811 8100

Natural Gas Technologies

Emerson Process Management

Regulator Technologies, Inc.

USA - Headquarters

McKinney, Texas 75070 USA

Tel: +1 800 558 5853

Outside U.S. +1 972 548 3574

Asia-Pacific

Singapore 128461, Singapore

Tel: +65 6770 8337
Europe

Bologna 40013, Italy

Tel: +39 051 419 0611

Chartres 28008, France

Tel: +33 2 37 33 47 00
Middle East and Africa

Dubai, United Arab Emirates

Tel: +971 4811 8100

TESCOM

Emerson Process Management

Tescom Corporation

USA - Headquarters

Elk River, Minnesota 55330-2445, USA

Tels: +1 763 241 3238

         +1 800 447 1250
Europe

Selmsdorf 23923, Germany

Tel: +49 38823 31 287 

Asia-Pacific

Shanghai 201206, China

Tel: +86 21 2892 9499

For further information visit www.fisherregulators.com 

Содержание EMERSON ACE95JR

Страница 1: ...allation operation and maintenance procedures performed by unqualified personnel may result in improper adjustment and unsafe operation Either condition may result in equipment damage or personal injury Use qualified personnel when installing operating and maintaining the Type ACE95jr Tank Blanketing Valve Scope of the Manual This Instruction Manual provides installation startup and maintenance pr...

Страница 2: ...emperature Capabilities 1 Nitrile NBR 20 to 180 F 29 to 82 C Fluorocarbon FKM 0 to 212 F 18 to 100 C Ethylenepropylene EPDM FDA 20 to 212 F 29 to 100 C Perfluoroelastomer FFKM 20 to 212 F 29 to 100 C Approximate Weight with all accessories 30 lbs 14 kg Table 1 Control Pressure Ranges Control PRESSURE RANGE SPRING RANGE SPRING MATERIAL SPRING FREE LENGTH SPRING WIRE DIAMETER In w c mbar In mm In mm...

Страница 3: ...hese components therefore the outlet control pressure of the unit is not affected by fluctuating inlet pressure Installation Warning Personal injury equipment damage or leakage due to escaping accumulated gas or bursting of pressure containing parts may result if this gas blanketing system is over pressured or installed where service conditions could exceed the limits given in the Specifications s...

Страница 4: ...ng operating and maintaining valves Before installing inspect the valve and tubing for any shipment damage or foreign material that may have collected Make certain the body interior is clean and the pipelines are free of foreign material Apply pipe compound only to the male pipe threads with a screwed body or use suitable line gaskets and good bolting practices with a flanged body 2 Inspect the na...

Страница 5: ...e contact Emerson for alternate methods of installation A single array manifold is available for such situations Gauges and Shutoff Valves Inlet gas shutoff valves are desirable for servicing If this Type ACE95jr tank blanketing valve was not ordered with an inlet pressure gauge it is advisable to install a gauge between the inlet shutoff valve and the blanketing valve Note Safety considerations m...

Страница 6: ...esive Loctite 222 spring case key 7 vent key 6 lock Nut key 3 adjusting screw key 2 actuator cap Key 1 Figure 4 Spring Case Adjusting Screw and Actuator Cap W8160 Be certain that nameplates are updated to accurately indicate any field changes in equipment materials service conditions or pressure settings Monthly Maintenance 1 Visually inspect the unit to ensure tight connections tight seals and sa...

Страница 7: ... Valve information is on the nameplate attached to the upper actuator case When performing disassembly or re assembly operations refer to Figure 6 for key numbers unless otherwise directed Disassembly Warning To avoid personal injury resulting from sudden release of pressure isolate the valve from all pressure and cautiously release trapped pressure from the valve before attempting disassembly Act...

Страница 8: ...ts inspect for unusual wear lightly lubricate all O rings and the groove that locates the rolling diaphragm bead See Figure 6 Cage Sub Assembly 1 Install the internal O rings key 16 into the body key 18 2 Place the rolling diaphragm key 38 over the threaded portion of the piston key 37 Use caution not to place the rolling diaphragm upside down refer to Figure 6 detail Apply Loctite 222 to the pist...

Страница 9: ...ing case gasket key 9 between the spring case key 7 and the upper actuator case key 33 before attaching the spring case to the upper actuator case Attach the spring case to the upper actuator case using hex head screws key 29 12 Place the upper actuator case key 33 over the range spring key 8 and lower actuator case key 30 13 Install hex head screws key 29 with lock washers key 28 and nuts key 31 ...

Страница 10: ...re 6 Type ACE95jr Tank Blanketing Valve Assembly main valve detail 42 41 52 39 38 37 36 1 2 3 4 6 9 13 10 11 12 48 14 15 16 18 7 5 8 33 29 31 28 30 29 27 29 28 162 locate groove in body for rolling diaphragm bead GC950201 ...

Страница 11: ...5 in w c 12 to 1 mbar GC053215X02 14 O ring Nitrile NBR GC070173X02 Ethylenepropylene EPDM FDA GC070173X52 Fluorocarbon FKM GC070173X12 Perfluoroelastomer FFKM GC070173X62 15 Diaphragm Bolt GC053210X02 Recommended Spare Part Key Description Part Number 16 O ring 2 required Nitrile NBR 1F115306992 Ethylenepropylene EPDM FDA 1F1153X0062 Fluorocarbon FKM 1F1153X0022 Perfluoroelastomber FFKM 1F1153X00...

Страница 12: ...aintenance of any Emerson Process Management Regulator Technologies Inc product remains solely with the purchaser Industrial Regulators Emerson Process Management Regulator Technologies Inc USA Headquarters McKinney Texas 75070 USA Tel 1 800 558 5853 Outside U S 1 972 548 3574 Asia Pacific Shanghai 201206 China Tel 86 21 2892 9000 Europe Bologna 40013 Italy Tel 39 051 419 0611 Middle East and Afri...