background image

www.Fisher.com

Fisher

r

 1052PSV Size 60 Rotary Actuator

Contents

Introduction

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Scope of Manual

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Specifications

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Description

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Principle of Operation

3

. . . . . . . . . . . . . . . . . . . . . . . . .

Installation

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Lifting Guidelines

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Conduit Connection

6

. . . . . . . . . . . . . . . . . . . . . . . . .

Valve Flow Direction

6

. . . . . . . . . . . . . . . . . . . . . . . . .

Actuator Mounting

6

. . . . . . . . . . . . . . . . . . . . . . . . . .

Precise Valve/Actuator Closed Position

and Turnbuckle Adjustment

8

. . . . . . . . . . . . . . . . .

Actuator Spring Adjustment

10

. . . . . . . . . . . . . . . . . .

Initial Setting

10

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Stroking Range

10

. . . . . . . . . . . . . . . . . . . . . . . . .

Accessory Mounting

11

. . . . . . . . . . . . . . . . . . . . . . . .

Maintenance

14

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Disassembly

15

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Assembly

17

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Troubleshooting

19

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Adjustable Travel Stops

20

. . . . . . . . . . . . . . . . . . . . . . .

Parts Ordering

20

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Spare Parts

21

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Parts List and Special Tools

23

. . . . . . . . . . . . . . . . . . . .

Figure 1. Fisher SS-84PSV4 Valve 
with 1052PSV Actuator and 3610J Positioner

W9722

Introduction

Scope of Manual

This instruction manual includes installation, adjustment, maintenance, and parts ordering information for the Fisher
1052PSV (Size 60) pneumatic spring-and-diaphragm rotary actuator (see figure 1).

The seismically qualified actuator design is based on the standard Fisher 1052 size 60 actuator. The 1052PSV size 60
actuator incorporates the tilting diaphragm rod, turnbuckle adjusting feature, upper diaphragm casing assembly, and
SS-129 dual springs mounted within a fabricated box construction. The actuator box is designed for standard 3610J
positioner mounting. Adjustable valve open position is provided by limiting lever rotation with adjustable travel limit
bolts in the bottom of the fabricated actuator box.

To ensure proper assembly, the Vee-Ball

t

, valve drive shaft, and actuator lever connections are a missing-tooth spline

design, allowing one-way only assembly.

Instructions for the control valve, positioner, and other accessories are covered in separate instruction manuals.

Do not install, operate, or maintain a 1052PSV actuator without being fully trained and qualified in valve, actuator, and
accessory installation, operation, and maintenance. To avoid personal injury or property damage, it is important to
carefully read, understand, and follow all the contents of this manual, including all safety cautions and warnings. If you
have any questions about these instructions, contact your Emerson Process Management sales office before
proceeding.

Instruction Manual

D103407X012

1052PSV Actuator

May 2011

Содержание 1052PSV

Страница 1: ...tuator incorporates the tilting diaphragm rod turnbuckle adjusting feature upper diaphragm casing assembly and SS 129 dual springs mounted within a fabricated box construction The actuator box is desi...

Страница 2: ...t Connections Standard 3 4 NPT internal thread Mounting Positions RH mount PDTO Vee Ball rotates CCW to close spring fail closed Approximate Weights 136 kg 300 lb Controller Positioners Available DVC2...

Страница 3: ...w 8 32 9 64 3 4 2 5 30 lbf in Description The 1052PSV diaphragm rotary actuator is a pneumatic spring return actuator for use with the SS 84PSV4 rotary shaft control valve The 1052PSV actuator can be...

Страница 4: ...additional measures that must be taken to protect against process media If installing into an existing application also refer to the WARNING at the beginning of the Maintenance section in this instruc...

Страница 5: ...to 20 lbf ft The assembly can now be lifted using a hoist capable of leveling these lifting points Lifting Valve Only To lift the valve insert 3 4 10 eyebolts into the two tapped holes on the top of...

Страница 6: ...Valve Flow Direction Valve construction can change the flow direction for a control valve assembly It is important to observe the flow direction in all valve applications before installing the valve i...

Страница 7: ...er key 27 is attached to the rod end bearing remove the cap screw and hex nut keys 18 and 19 8 If the 1052PSV spring adjustment has been changed complete the Initial Setting portion of the 1052PSV Spr...

Страница 8: ...3 A regulated air supply with appropriate gauge will be required to stroke the actuator The following wrench sizes will be used to adjust the turnbuckle 1 5 16 inch wrench for the turnbuckle key 57 15...

Страница 9: ...the turnbuckle key 57 with a 1 5 16 inch wrench and recheck Continue this procedure until the valve is in the closed position when the actuator is resting on its up travel stop Figure 7 Accessory Moun...

Страница 10: ...n disassembled or if the spring adjustment was changed and it is desired to match the initial setting stated on the nameplate make sure the rod end bearing key 17 figure 13 has been disconnected from...

Страница 11: ...screws and nuts keys 22 and 21 including washers key 39 into the actuator box until each cap screw just touches the lever key 27 without torquing Using a 1 7 16 inch wrench tighten the nuts key 21 to...

Страница 12: ...cap screws and tighten to 23 NSm 17 lbfSft with a 1 2 inch wrench Fisher 67CFSR Mounting Install two 67CFSR regulators to opposite sides of the 7 inch upper tube of the actuator box key 14 Apply thre...

Страница 13: ...bly the pressure connection to the actuator will normally be made at the factory 3 When the control valve is completely installed and connected to the instrument check for correct action air to open t...

Страница 14: ...torque to 47 N m 35 lbf ft Apply thread locking adhesive medium strength key 77 to the GO switch 5 8 18 threads and torque to 47 N m 35 lbf ft 8 Return the valve back to the closed position and verify...

Страница 15: ...diaphragm casing key 1 Failure to do so will allow the spring precompression to rotate the valve beyond its fully open or closed position This could cause damage to the valve components and or seal 1...

Страница 16: ...way from the actuator relieve 1052PSV spring compression before proceeding further 9 To relieve spring compression use the special 2 1 2 inch wrench to rotate the spring adjustor key 74 and move it aw...

Страница 17: ...ring adjustor key 74 by insertion into the window in the middle of the upper actuator tube Coat both sides of the needle thrust bearing key 71 with nuclear grade anti seize lubricant key 30 place betw...

Страница 18: ...tightened should be diametrically opposed and 90 degrees apart Tighten these four hex nuts to 13 6 NSm 10 lbfSft b Tighten the remaining hex nuts in a clockwise criss cross pattern to 13 6 NSm 10 lbf...

Страница 19: ...cket key 24 to the actuator box using 3 8 16 x 0 75 cap screws key 23 and washers key 40 only when bracket is painted Using a 9 16 inch wrench tighten to 41 NSm 30 lbfSft 30 Install the travel indicat...

Страница 20: ...e diaphragm casing while using a digital protractor to position the valve to the desired rotation Using the top of the valve body as a reference for 0 degrees rotate the valve until the square on the...

Страница 21: ...hragm size 60 Key 3 1 Non Safety Related O n Recommendation to purchase this spare part is based on shelf life restrictions The diaphragm is a key component within the actuator construction required t...

Страница 22: ...Instruction Manual D103407X012 1052PSV Actuator May 2011 22 Figure 13 Fisher 1052PSV Actuator Assembly GE39246 D...

Страница 23: ...E39230X012 25 Washer Plain 3 8 6 1B365428992 26 Washer Plain 3 8 48 1B365428992 27 Lever 1 GE39229X012 28 Cap Screw Hex Hd 5 8 11X1 25 1 12A9405X022 29 Hub 1 GE39223X022 30 Nuclear Grade Anti Seize Lu...

Страница 24: ...ailable upon request We reserve the right to modify or improve the designs or specifications of such products at any time without notice Neither Emerson Emerson Process Management nor any of their aff...

Отзывы: