Material Compatibility

The interior cabinet of this unit is constructed of epoxy-
coated steel. Care must be exercised when determining 
which chemicals may be stored in the refrigerator and
freezer sections and which type of storage materials
should be employed.

ABS Plastic deteriorates when exposed to, but not limited
to, the following:
Aliphatic Hydrocarbons; Aromatic Hydrocarbons; Fully
and Partially Halogenated Hydrocarbons; Alcohols
Monohydric; Phenols; Ketones; Esters; Ethers; Organic
Acids (concentrates and dilute); and Concentrated
Oxidizing Acids. This information is taken from Plastics
Edition 8 Thermoplastics and Thermosets published by  
D.A.T.A. and The International Plastics Selector, Inc.
Cordura Companies 
9889 Willow Creek Road 
P.O. Box 26637 
San Diego, California  92126 

Aluminum Alloys are susceptible to corrosion when
exposed to but not limited to most inorganic acids, bases
and salts with a pH outside of their passive range of pH 4
to 9. It is also important to recognize that the compatibility
of aluminum alloys with mixtures of organic compounds
cannot always be predicted from their compatibility with
each of the compounds. For example, some aluminum
alloys are corroded severely in mixtures of carbon tetra-
chloride and methyl alcohol, even though they are resist-
ant to each compound alone. This information is taken
from  Corrosion and Corrosion Protection Handbook
Second Edition 
Published by  
Marcel Dekker, Inc.
270 Madison Ave.
New York, NY  10016 

O

PERATION

7

Содержание Isotemp 150

Страница 1: ...Isotemp Explosion Proof Refrigerators and Freezers Refrigerator Model 153 153HK Freezer Model 150 150HK 104354 9 15 06...

Страница 2: ...5 Leveling The Unit 5 Shelves 5 Electrical Connection 5 Operation 6 Initial Startup 6 Temperature Control 6 Condensate Disposal 6 Material Compatibility 7 Troubleshooting 8 Maintenance 9 Cabinet Clea...

Страница 3: ...lication alterations or modifications will void the Warranty This apparatus is designed for use in Class I II or III loca tions as defined by the National Electrical Code unless otherwise noted Safety...

Страница 4: ...ibe such exter nal evidence of loss or damage may result in the carrier s refusing to honor your damage claim The form required to file such a claim will be supplied by the carrier Concealed Loss or D...

Страница 5: ...if it is left halfway open Shelves Shipped inside each cabinet are four fixed shelves which also serve as part of the evaporator coil Electrical Connection Determine the total amount of current prese...

Страница 6: ...Remove the two screws with a flat blade screw driver for access For operation above an altitude of 3000 ft have the thermo stat adjusted by a technician Condensate Disposal The condensate drain is at...

Страница 7: ...d by D A T A and The International Plastics Selector Inc Cordura Companies 9889 Willow Creek Road P O Box 26637 San Diego California 92126 Aluminum Alloys are susceptible to corrosion when exposed to...

Страница 8: ...rcuit Check fuse or circuit breaker at breaker breaker box Runs Continuously Frost buildup on refrigeration coils Defrost unit Clicking Sound The compressor is equipped Disconnect power Allow refriger...

Страница 9: ...of water is recommended for cleaning the interior and exterior of the cabinet All surfaces should be rinsed and thoroughly dried Condenser The condenser coil is located behind the sides and top exter...

Страница 10: ...C 4 C at 20 C 4 C Electrical Requirements 13 986 150 115 Volts 10 60 Hz 5 0 Amps 13 986 150HK 220 Volts 10 50 Hz 5 0 Amps 13 986 153 115 Volts 10 60 Hz 5 0 Amps 13 986 153HK 220 Volts 10 50 Hz 5 0 Am...

Страница 11: ...11...

Страница 12: ...adjustment is reasonable in the light of the manufacturer s own warranty b The Company shall be released from all obligations under its warranty in the event repairs or modifications are made by perso...

Отзывы: