Unpacking

Save all packing material if apparatus is received dam-
aged. This merchandise was carefully packed and thor-
oughly inspected before leaving our factory.

Responsibility for its safe delivery was assumed by the
carrier upon acceptance of the shipment; therefore, claims
for loss or damage sustained in transit must be made
upon the carrier by the recipient as follows:

Visible Loss or Damage 

Note any external evidence of loss or damage on the
freight bill, or express receipt, and have it signed by the
carrier’s agent. Failure to adequately describe such exter-
nal evidence of loss or damage may result in the carrier’s
refusing to honor your damage claim. The form required
to file such a claim will be supplied by the carrier.

Concealed Loss or Damage 

Concealed loss or damage refers to loss or damage
which does not become apparent until the merchandise
has been unpacked and inspected. Should either occur,
make a written request for the carrier’s agent within 15
days of the delivery date; then file a claim with the carrier
since the damage is the carrier’s responsibility.

If you follow the above instructions carefully, we will 
guarantee our full support of your claim to be compensat-
ed for loss from concealed damage.

DO NOT – FOR ANY REASON – RETURN THIS UNIT 
WITHOUT FIRST OBTAINING AUTHORIZATION

Содержание Isotemp 150

Страница 1: ...Isotemp Explosion Proof Refrigerators and Freezers Refrigerator Model 153 153HK Freezer Model 150 150HK 104354 9 15 06...

Страница 2: ...5 Leveling The Unit 5 Shelves 5 Electrical Connection 5 Operation 6 Initial Startup 6 Temperature Control 6 Condensate Disposal 6 Material Compatibility 7 Troubleshooting 8 Maintenance 9 Cabinet Clea...

Страница 3: ...lication alterations or modifications will void the Warranty This apparatus is designed for use in Class I II or III loca tions as defined by the National Electrical Code unless otherwise noted Safety...

Страница 4: ...ibe such exter nal evidence of loss or damage may result in the carrier s refusing to honor your damage claim The form required to file such a claim will be supplied by the carrier Concealed Loss or D...

Страница 5: ...if it is left halfway open Shelves Shipped inside each cabinet are four fixed shelves which also serve as part of the evaporator coil Electrical Connection Determine the total amount of current prese...

Страница 6: ...Remove the two screws with a flat blade screw driver for access For operation above an altitude of 3000 ft have the thermo stat adjusted by a technician Condensate Disposal The condensate drain is at...

Страница 7: ...d by D A T A and The International Plastics Selector Inc Cordura Companies 9889 Willow Creek Road P O Box 26637 San Diego California 92126 Aluminum Alloys are susceptible to corrosion when exposed to...

Страница 8: ...rcuit Check fuse or circuit breaker at breaker breaker box Runs Continuously Frost buildup on refrigeration coils Defrost unit Clicking Sound The compressor is equipped Disconnect power Allow refriger...

Страница 9: ...of water is recommended for cleaning the interior and exterior of the cabinet All surfaces should be rinsed and thoroughly dried Condenser The condenser coil is located behind the sides and top exter...

Страница 10: ...C 4 C at 20 C 4 C Electrical Requirements 13 986 150 115 Volts 10 60 Hz 5 0 Amps 13 986 150HK 220 Volts 10 50 Hz 5 0 Amps 13 986 153 115 Volts 10 60 Hz 5 0 Amps 13 986 153HK 220 Volts 10 50 Hz 5 0 Am...

Страница 11: ...11...

Страница 12: ...adjustment is reasonable in the light of the manufacturer s own warranty b The Company shall be released from all obligations under its warranty in the event repairs or modifications are made by perso...