24
@0
GAS CONVERSION
Adjusting the cooktop burner minimums
When switching from one type of gas to another, the minimum
flow rate must also be correct:
●
The flame should not go out even when passing suddenly from
maximum to minimum flame.
To regulate the flame follow these instructions:
Semi-rapid burner (A)
●
Light the burner
●
Set the gas valve to
position (minimum rate)
●
Remove the dial.
●
With a thin screwdriver, turn the regulation screw inside the tap rod
until adjustment is correct
Inside crown of DUAL burner (B)
●
Light the dual burner
●
Set the gas valve to
position (minimum rate of inner crown)
●
Remove the dial
●
With a thin screwdriver, turn the regulation screw until adjustment is correct.
●
The screw is accessible via a hole in the microswitch.
Outside crown of DUAL burner (C)
●
Light the dual burner
●
Set the gas valve to
position
(minimum rate of outer crown and maximum rate of inner crown).
●
Remove the dial
●
With a thin screwdriver, turn the regulation screw inside the tap rod
until adjustment is correct
For LP/PROPANE gas, tighten the adjustmentacrews completely.
A Regulation screw (Triple-Ring and Semi-Rapid burner)
B Regulation screw (Inner crown of dual burner)
C Regulation screw (Outer crown of dual burner)
A
C
B
Regulation
screws
Regulation
screws
Regulation
screws